Key result
Cutting balloon angioplasty for carotid in-stent restenosis achieved complete angiographic resolution or residual stenosis of <30% in >90% of evaluated patients.
Why the study?
Is cutting balloon angioplasty safe and effective for treating carotid in-stent restenosis?
Case Report (n=16)
Is cutting balloon angioplasty safe and effective for treating carotid in-stent restenosis?
Cutting balloon angioplasty appears to be a safe and effective alternative treatment for carotid in-stent restenosis, achieving high rates of angiographic resolution without always requiring additional stents.
Answers are grounded in this paper and cite their sources.
May support cutting balloon use in carotid in-stent restenosis; hypothesis-generating case data leave comparative efficacy and durability open.
Percutaneous stenting techniques are becoming more commonly used for treatment of carotid artery disease. One outcome of particular concern is in-stent restenosis. Indications for treatment of in-stent restenosis are not clearly defined. Use of traditional balloon angioplasty with or without stent placement is still considered the first option. Cutting balloon angioplasty has recently been used as an alternative treatment option for revascularization of in-stent restenosis with higher procedural success rates and without the use of additional stents. We report our experience with cutting balloon angioplasty in treating 2 patients with carotid in-stent restonosis, and review previous cases reported in the literature. A total of 16 patients have been treated with cutting balloon angioplasty. Among 11 patients for whom the clinical and angiographic information were available, 63% of patients were asymptomatic at the time of treatment, and more than 90% of patients showed either complete angiographic resolution or residual stenosis of less than 30%. Additional stent placement or angioplasty was required in only half of the patients, and 1 patient had recurrent stenosis. The review suggests that the procedure is safe and effective.
No takes yet. Share an insight, caveat, or question.
Shah et al. (2008) conducted a case report in Carotid in-stent restenosis (n=16). Cutting balloon angioplasty was evaluated on Complete angiographic resolution or residual stenosis of less than 30%. Cutting balloon angioplasty for carotid in-stent restenosis achieved complete angiographic resolution or residual stenosis of <30% in >90% of evaluated patients.