Key result
Fluctuating shear stress created by a typical handgrip protocol did not alter the initial phase of brachial artery flow-mediated dilation compared to stable shear stress.
Why the study?
Does a fluctuating shear stress stimulus alter the brachial artery flow-mediated dilation response compared to a stable shear stimulus in healthy subjects?
Does a fluctuating shear stress stimulus alter the brachial artery flow-mediated dilation response compared to a stable shear stimulus in healthy subjects?
The endothelium transduces mean shear stress regardless of fluctuations created by handgrip exercise, suggesting forearm exercise is a viable technique to investigate brachial artery FMD.
Answers are grounded in this paper and cite their sources.
Handgrip remains viable for brachial FMD testing; extends evidence that healthy endothelium transduces mean shear but leaves generalizability open.
Exercise elevates shear stress in the supplying conduit artery. Although this is the most relevant physiological stimulus for flow-mediated dilation (FMD), the fluctuating pattern of shear that occurs may influence the shear stress-FMD stimulus response relationship. This study tested the hypothesis that the brachial artery FMD response to a step increase in shear is influenced by the fluctuating characteristics of the stimulus, as evoked by forearm exercise. In 16 healthy subjects, we examined FMD responses to step increases in shear rate in three conditions: stable shear upstream of heat-induced forearm vasodilation (FHStable); fluctuating shear upstream of heat-induced forearm vasodilation and rhythmic forearm cuff inflation/deflation (FHFluctuating); and fluctuating shear upstream of exercise-induced forearm vasodilation (FEStep Increase). The mean increase in shear rate (+/-SD) was the same in all trials (FHFluctuating): 51.69 +/- 15.70 s(-1); FHStable: 52.16 +/- 14.10 s(-1); FEStep Increase: 50.14 +/- 13.03 s(-1) P = 0.131). However, the FHFluctuating and FEStep Increase trials resulted in a fluctuating shear stress stimulus with rhythmic high and low shear periods that were 96.18 +/- 24.54 and 11.80 +/- 7.30 s(-1), respectively. The initial phase of FMD (phase I) was followed by a second, delayed-onset FMD and was not different between conditions (phase I: FHFluctuating: 5.63 +/- 2.15%; FHStable: 5.33 +/- 1.85%; FEStep Increase: 5.30 +/- 2.03%; end-trial: FHFluctuating: 7.76 +/- 3.40%; FHStable: 7.00 +/- 3.03%; FEStep Increase: 6.68 +/- 3.04%; P = 0.196). Phase I speed also did not differ (P = 0.685). In conclusion, the endothelium transduced the mean shear when exposed to shear fluctuations created by a typical handgrip protocol. Muscle activation did not alter the FMD response. Forearm exercise may provide a viable technique to investigate brachial artery FMD in humans.
No takes yet. Share an insight, caveat, or question.
Pyke et al. (2008) studied Healthy (n=16). Fluctuating shear stress (handgrip exercise or cuff inflation) vs. Stable shear stress was evaluated on Initial phase of flow-mediated dilation (phase I) (p=0.196). Fluctuating shear stress created by a typical handgrip protocol did not alter the initial phase of brachial artery flow-mediated dilation compared to stable shear stress.
Synapse has enriched 10 related papers. Consider them for comparative context: