Key result
TAVR for failed aortic homografts resulted in 0% 30-day mortality, stroke, or pacemaker implantation, comparable to TAVR for stented bioprostheses.
Why the study?
Surgical reoperation for aortic homograft structural valve degeneration is high risk, and while TAVR is an alternative, descriptions of implantation techniques are limited.
Does TAVR for failed aortic homografts have comparable safety and feasibility to TAVR for stented aortic bioprostheses in patients with structural valve degeneration?
Cohort (n=41)
Does TAVR for failed aortic homografts have comparable safety and feasibility to TAVR for stented aortic bioprostheses in patients with structural valve degeneration?
Absolute Event Rate: 0% vs 0%
TAVR for failing aortic homografts appears feasible and safe with zero 30-day mortality, though precise ventricular positioning is crucial to prevent late device migration.
Suggests TAVR feasibility for failed homografts with favorable short-term safety; hypothesis-generating and warrants further prospective evaluation.
OBJECTIVE: Surgical reoperation for aortic homograft structural valve degeneration (SVD) is a high-risk procedure. Transcatheter aortic valve replacement (TAVR) for homograft-SVD is an alternative to reoperation, but descriptions of implantation techniques are limited. This study compares outcome in patients undergoing into two groups by the type of previously implanted aortic valve prosthesis: TAVR for failed aortic homografts (TAVR-H) or for stented aortic bioprostheses (TAVR-BP). METHODS: From 2015 to 2017, TAVR was performed in 41 patients with SVD. Thirty-three patients in the TAVR-BP group (six for SVD of valved conduits), and eight patients in the TAVR-H group. The Valve Academic Research Consortium criteria were used for outcome reporting purposes. RESULTS: The patients with TAVR-BP had predominant prosthetic stenosis (94%, p = .002), whereas TAVR-H individuals presented mostly with regurgitation (88%, p = <.001). Patients with TAVR-H received: Sapien-3 (6), Sapien-XT (1), and CoreValve (1) devices. Low, 40% ventricular fixation in relation to homograft annulus was attempted to anchor the prosthesis on the homograft suture-line. One patient with TAVR-BP experienced intraoperative distal prosthesis migration and Type-B aortic dissection, and two patients in the TAVR-H group had late postoperative proximal device migration. In both groups, there was zero 30-day mortality, stroke, or pacemaker implantation. CONCLUSIONS: TAVR for failing aortic homografts may be a feasible and safe alternative to high-risk surgical reintervention. Precise, 40%-ventricular device positioning appears crucial for prevention of late paravalvular leak/late prosthesis migration and minimizing the risk of repeat surgical intervention.
No takes yet. Share an insight, caveat, or question.
Kislitsina et al. (2020) conducted a cohort in Structural valve degeneration (SVD) (n=41). TAVR for failed aortic homografts (TAVR-H) vs. TAVR for stented aortic bioprostheses (TAVR-BP) was evaluated on 30-day mortality, stroke, or pacemaker implantation. TAVR for failed aortic homografts resulted in 0% 30-day mortality, stroke, or pacemaker implantation, comparable to TAVR for stented bioprostheses.