Key result
Valve-in-valve TAVR into a failing aortic root homograft successfully improved pulmonary artery pressure, valvular regurgitation, and symptoms in a 21-year-old woman with a complex surgical history.
Why the study?
Does valve-in-valve TAVR improve hemodynamics and symptoms in a young patient with aortic homograft failure and high surgical risk?
Case Report (n=1)
Does valve-in-valve TAVR improve hemodynamics and symptoms in a young patient with aortic homograft failure and high surgical risk?
Valve-in-valve TAVR may serve as a viable, less invasive alternative to repeat sternotomy in young patients with complex surgical histories and failing aortic homografts.
May support valve-in-valve TAVR feasibility in select high-risk young patients; hypothesis-generating and requires prospective studies before wider consideration.
Transcatheter aortic valve replacement (TAVR) is a well-established method for replacing native aortic valves; however, it was conceived for elderly patients with aortic valve stenosis, and the lack of data on long-term durability has led practitioners to restrict the use of TAVR to patients who have short life expectancies. Here, we describe the case of a 21-year-old woman who had undergone 3 previous open aortic valve replacements and who presented with symptoms of recurrent valvular failure. Transthoracic echocardiograms and computed tomographic angiograms revealed a degenerating aortic root homograft with substantial calcification, moderate-to-severe aortic valve stenosis, and severe aortic valve regurgitation. Open surgical valve replacement posed substantial risk to our patient, so we decided to perform valve-in-valve TAVR with use of the Edwards Sapien XT Transcatheter Heart Valve. The patient's pulmonary artery pressure, valvular regurgitation, and symptoms improved substantially thereafter. We found that valve-in-valve TAVR into a failing aortic root homograft was less invasive than repeat surgical valve replacement in this young patient who had congenital vascular anomalies and a complex surgical history.
No takes yet. Share an insight, caveat, or question.
Díez et al. (2016) conducted a case report in Aortic homograft failure (n=1). Valve-in-valve TAVR (Edwards Sapien XT Transcatheter Heart Valve) was evaluated on Improvement in pulmonary artery pressure, valvular regurgitation, and symptoms. Valve-in-valve TAVR into a failing aortic root homograft successfully improved pulmonary artery pressure, valvular regurgitation, and symptoms in a 21-year-old woman with a complex surgical history.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: