Synapse
⌘+K
Synapse
PulseExploreClubsResearchersJournals
Instagram
HomeClubsExplore
May 9, 2008Journal of Applied PhysiologyOpen Access

Breath-hold diving at 5-m depth significantly reduced cardiac output to 3.8 L/min compared to 6.3 L/min at baseline, indicating a constrictive effect on the heart from increased environmental pressure.

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Does breath-hold diving at 5-m depth alter cardiac output and left ventricular diastolic function in healthy humans?

Population

12 healthy male subjects, experienced active breath-hold divers, with no history of cardiovascular or…

Comparison

Breath-hold diving at 5-m depth and other… vs Out of water condition and comparisons between…

Design

Cohort, Analysis was made offline by an expert in Doppler-echocardiography…

Key result

Breath-hold diving at 5-m depth significantly reduced cardiac output to 3.8 L/min compared to 6.3 L/min at baseline, indicating a constrictive effect on the heart from increased environmental pressure.

Authors

CMC MarabottiASAlessandro ScalziniDCDanilo Cialoni

Discussion

Loading...

Member takes

Overview

May warrant caution in breath-hold divers with cardiac conditions; leaves open effects at greater depths or in disease.

Study Design

Type

Observational (n=12)

Multicenter

No

Structured PICO

Does breath-hold diving at 5-m depth alter cardiac output and left ventricular diastolic function in healthy humans?

P
Population
12 healthy male experienced breath-hold divers underwent underwater echocardiography to evaluate cardiovascular responses to immersion and diving.
E
Exposure
Breath-hold diving at 5-m depth (condition D) and other immersion conditions (head-out immersion, full immersion at surface breathing, full immersion at surface breath-holding).
C
Comparator
Out of water (basal) condition and comparisons between different immersion states.
O
Outcome
Changes in heart rate, left ventricular volumes, stroke volume, cardiac output, and left ventricular diastolic function indexes (E peak, A peak, E/A, DTE) measured by underwater two-dimensional Doppler echocardiography.surrogate

Main Result

Absolute Event Rate: 3.8% vs 6.3%

p-value: p=<0.001

Breath-hold diving at 5-m depth induces a significant reduction in cardiac output and left ventricular volumes, likely due to increased environmental pressure causing a constrictive effect on the heart.

Limitations

  • Small sample size
  • Only male subjects were included
  • The sequence of echocardiographic studies could not be randomized due to technical difficulties
  • Echocardiography may be inefficient in accurately detecting small changes in right ventricle dimensions
  • Absence of female subjects
  • Time necessary for handling equipment prevented consecutive testing of all conditions in each subject
  • Only apical four-chamber view and transmitral flow recorded during diving to minimize duration
  • Intrinsic inefficiency of echocardiography in accurately detecting small changes in right ventricle dimensions

Cite This Study

Marabotti et al. (2008) conducted an observational in Healthy (n=12). Breath-hold diving at 5-m depth vs. Out of water (basal) and surface immersion was evaluated on Cardiac output (p=<0.001). Breath-hold diving at 5-m depth significantly reduced cardiac output to 3.8 L/min compared to 6.3 L/min at baseline, indicating a constrictive effect on the heart from increased environmental pressure.

synapsesocial.com/papers/6a75ddc54555d8f90b706f97https://doi.org/10.1152/japplphysiol.00126.2008
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Features of hemodynamics of pulmonary circulation during the diving reflex2020 · 5 citations
  2. 2Cardiovascular effects of breath-hold diving at altitude2024
  3. 3Long‐term effects of frequent maximal breath‐holding on the cardiac health of elite freedivers2015 · 16 citations
  4. 4Heart rate profiles and heart rate variability during scuba diving2021 · 15 citations
  5. 5Diving response and arterial oxygen saturation during apnea and exercise in breath-hold divers2002 · 146 citations