Why the study?
Determining proper material parameters from clinical data is a major challenge in patient-specific computational cardiovascular modeling, prompting investigation into whether pulse wave velocity can guide parameter estimation for the GOH constitutive model.
Pulse wave velocity measurements at diastolic and dicrotic notch pressures can significantly reduce the parameter space and uncertainty in patient-specific computational arterial biomechanical models.
Answers are grounded in this paper and cite their sources.
PWV may aid GOH parameter selection in patient-specific models; leaves open clinical utility pending prospective validation.
Determining proper material parameters from clinical data remains a large, though unavoidable, challenge in patient-specific computational cardiovascular modeling. In an attempt to couple the clinical and modelling practice, this study investigated whether pulse wave velocity (PWV), a clinical arterial stiffness measure, can guide in determining appropriate parameter values for the Gasser-Ogden-Holzapfel (GOH) constitutive model. The reduction and uncertainty analysis was demonstrated on a cylindrical descending thoracic aorta model. Starting from discretized ranges of GOH parameters and using a full factorial design, the parameter sets yielding a physiological PWV (3.5–12.5 m/s) at diastolic pressure (80 mmHg; PWV80) were selected and their PWV at dicrotic notch pressure (110 mmHg; PWV110) was determined. These PWV measures were applied to determine the reduction of the 7D GOH parameter space, the 2D subspaces and the remaining uncertainty in case only PWV80 or both measurements are available. The resulting 12,032 parameter sets lead to a 7D parameter space reduction of ≥ 82.5 % using PWV80, which increased to 96.0 % when including PWV110, in particular at 3.5–8.5 m/s. A similar trend was observed for the remaining uncertainty and the 2D subspaces comprised of medial collagen fiber parameters, while scarce reductions were found for the adventitial and elastin parameters. In conclusion, PWV80 and PWV110 are complementary measures with the potential to reduce the GOH parameter space in arterial models, in particular for media- and collagen-related parameters. Moreover, this approach has the advantage that it allows the estimation of the remaining uncertainty after parameter space reduction.
No takes yet. Share an insight, caveat, or question.
Gheysen et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: