Answers are grounded in this paper and cite their sources.
Proposes a simple but robust model independent self-tuning scheme for fuzzy logic controllers (FLCs). Here, the output scaling factor (SF) is adjusted online by fuzzy rules according to the current trend of the controlled process. The rule-base for tuning the output SF is defined on error (e) and change of error (/spl Delta/e) of the controlled variable using the most natural and unbiased membership functions (MFs). The proposed self-tuning technique is applied to both PI- and PD-type FLCs to conduct simulation analysis for a wide range of different linear and nonlinear second-order processes including a marginally stable system where even the well known Ziegler-Nichols tuned conventional PI or PID controllers fail to provide an acceptable performance due to excessively large overshoot. Performances of the proposed self-tuning FLCs are compared with those of their corresponding conventional FLCs in terms of several performance measures such as peak overshoot, settling time, rise time, integral absolute error and integral-of-time-multiplied absolute error, in addition to the responses due to step set-point change and load disturbance and, in each case, the proposed scheme shows a remarkably improved performance over its conventional counterpart.
No takes yet. Share an insight, caveat, or question.
Mudi et al. (1999) studied this question.