Why the study?
The study aimed to assess the reliability and reproducibility of a self-administered 6-min walk test in asymptomatic adults using a free smartphone app.
Does a self-administered 6-minute walk test using a free smartphone app provide reliable and reproducible results compared to supervised tests in asymptomatic adults?
Does a self-administered 6-minute walk test using a free smartphone app provide reliable and reproducible results compared to supervised tests in asymptomatic adults?
A self-administered 6-minute walk test using a free smartphone app is highly reliable and reproducible in asymptomatic adults, offering a practical tool for community-based fitness assessment.
Answers are grounded in this paper and cite their sources.
Self-administered smartphone 6MWT may enable convenient CRF tracking in asymptomatic adults; leaves open validation against clinical outcomes before broader adoption.
Background: The 6-min walk test (6MWT) is a simple, inexpensive, reliable, and reproducible test that provides a reasonable estimate of the cardiorespiratory fitness (CRF). We aimed to assess the reliability and reproducibility of a self-administered 6MWT in asymptomatic adults using a free smartphone app. Methods: In the 1st phase, 93 participants underwent a supervised 6MWT (6MWTsup) in a 30 m indoor corridor, using a triaxial accelerometer and their smartphones to compare the total step counts and to develop a 6-min walk distance (6MWD) prediction equation. In the 2nd phase, 25 participants performed the 6MWTsup and two self-administered 6MWTs outdoors (6MWTsa1 and 6MWTsa2, at least 48 h apart) using a free smartphone app. Results: The agreement between accelerometer- and app-based total step counts was limited (mean difference, −58.7 steps (−8.7%): 95% confidence interval, −326.5 (−46.8%) to 209.1 (29.3%)). The best algorithm for predicting the 6MWTsupm included: 795.456 + (0.815 heightm app-steps) − (1.620 ageyears) − (3.005 weightkg) − (1.155 app-steps), R2 = 0.609). The intraclass correlation coefficient between 6MWTsa2 and 6MWTsa1 was excellent (0.91: 0.81–0.96). The coefficient of variation was 6.4%. The agreement between the two self-administered tests was narrow (−1.9 (0.2%) meters: −57.4 (−9.5%) to 61.3 (9.9%)). Conclusions: The self-administered 6MWT has excellent reliability and reproducibility in asymptomatic adults, being a valuable tool for assessing CRF in community-based interventions.
No takes yet. Share an insight, caveat, or question.
Jesus et al. (2022) studied this question.