Why the study?
Does intensivist-performed bedside ultrasonography measurement of IVC collapsibility index correlate with invasive CVP in SICU patients?
Does intensivist-performed bedside ultrasonography measurement of IVC collapsibility index correlate with invasive CVP in SICU patients?
Intensivist-performed bedside ultrasonography of the IVC collapsibility index correlates significantly with invasive CVP, offering a noninvasive method for volume status assessment in the SICU.
Answers are grounded in this paper and cite their sources.
May support noninvasive volume assessment in SICU; leaves open prospective outcome validation before practice change.
BACKGROUND: Volume status assessment is an important aspect of patient management in the surgical intensive care unit (SICU). Echocardiologist-performed measurement of IVC collapsibility index (IVC-CI) provides useful information about filling pressures, but is limited by its portability, cost, and availability. Intensivist-performed bedside ultrasonography (INBU) examinations have the potential to overcome these impediments. We used INBU to evaluate hemodynamic status of SICU patients, focusing on correlations between IVC-CI and CVP. STUDY DESIGN: Prospective evaluation of hemodynamic status was conducted on a convenience sample of SICU patients with a brief (3 to 10 minutes) INBU examination. INBU examinations were performed by noncardiologists after 3 hours of didactics in interpreting and acquiring two-dimensional and M-mode images, and > or =25 proctored examinations. IVC-CI measurements were compared with invasive CVP values. RESULTS: Of 124 enrolled patients, 101 had CVP catheters (55 men, mean age 58.3 years, 44.6% intubated). Of these, 18 patients had uninterpretable INBU examinations, leaving 83 patients with both CVP monitoring devices and INBU IVC evaluations. Patients in three IVC-CI ranges (<0.20, 0.20 to 0.60, and >0.60) demonstrated significant decrease in mean CVP as IVC-CI increased (p = 0.023). Although <5% of patients with IVC-CI <0.20 had CVP <7 mmHg, >40% of this group had a CVP >12 mmHg. Conversely, >60% of patients with IVC-CI >0.6 had CVP <7 mmHg. CONCLUSIONS: Measurements of IVC-CI by INBU can provide a useful guide to noninvasive volume status assessment in SICU patients. IVC-CI appears to correlate best with CVP in the setting of low (<0.20) and high (>0.60) collapsibility ranges. Additional studies are needed to confirm and expand on findings of this study.
No takes yet. Share an insight, caveat, or question.
Stawicki et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: