Why the study?
To determine whether catheter-tissue interaction information, such as electrical coupling index or contact force, reduces time to achieve bidirectional cavotricuspid isthmus block during AFL ablation.
Does the visibility of electrical coupling index (ECI) or contact force (CF) reduce time to achieve bidirectional cavotricuspid isthmus block in patients with paroxysmal or persistent atrial flutter undergoing ablation?
Does the visibility of electrical coupling index (ECI) or contact force (CF) reduce time to achieve bidirectional cavotricuspid isthmus block in patients with paroxysmal or persistent atrial flutter undergoing ablation?
Answers are grounded in this paper and cite their sources.
The visibility of electrical coupling index during atrial flutter ablation significantly reduces the procedural time required to achieve bidirectional cavotricuspid isthmus block.
INTRODUCTION: Electrical coupling index (ECI) and contact force (CF) have been developed to aid lesion formation during catheter ablation. ECI measures tissue impedance and capacitance whilst CF measures direct contact. The aim was to determine whether the presence of catheter / tissue interaction information, such as ECI and CF, reduce time to achieve bidirectional cavotricuspid isthmus block during atrial flutter (AFL) ablation. METHODS: Patients with paroxysmal or persistent AFL were randomised to CF visible (range 5-40g), CF not visible, ECI visible (change of 12%) or ECI not visible. Follow-up occurred at 3 and 6 months and included a 7 day ECG recording. The primary endpoint was time to bidirectional cavotricuspid isthmus block. RESULTS: 114 patients were randomised, 16 were excluded. Time to bidirectional block was significantly shorter when ECI was visible (median 30.0 mins (IQR 31) to median 10.5mins (IQR 12) p 0.023) versus ECI not visible. There was a trend towards a shorter time to bidirectional block when CF was visible. Higher force was applied when CF was visible (median 9.03g (IQR 7.4) vs. 11.3g (5.5) p 0.017). There was no difference in the acute recurrence of conduction between groups. The complication rate was 2%, AFL recurrence was 1.1% and at 6 month follow-up, 12% had atrial fibrillation. CONCLUSION: The use of tissue contact information during AFL ablation was associated with reduced time taken to achieve bidirectional block when ECI was visible. Contact force data improved contact when visible with a trend towards a reduction in the procedural endpoint. ClinicalTrials.gov trial identifier: NCT02490033.
No takes yet. Share an insight, caveat, or question.
Begg et al. (2019) studied this question.