Why the study?
Continuous cardiac monitoring during treadmill testing is impossible and maintaining an optimal acoustic window during cycle ergometer exercise is difficult.
Does a probe fixation device allow for feasible continuous hands-free monitoring of echocardiographic images during physical exercise?
Does a probe fixation device allow for feasible continuous hands-free monitoring of echocardiographic images during physical exercise?
A probe fixation device enables continuous echocardiographic imaging during physical exercise with sufficient diagnostic image quality in the majority of tests, though its use is primarily limited to male patients.
Answers are grounded in this paper and cite their sources.
Supports feasibility of hands-free continuous monitoring during exercise echocardiography; requires validation in larger prospective studies before adoption.
BACKGROUND: Stress echocardiography has been widely used in clinical practice for decades and has recently gained even more importance in diagnostic approaches to ischemic heart disease. However, it still has numerous limitations. Despite advantages of physical exercise as most physiologic stressor, it is impossible to continuously monitor the cardiac function during treadmill test and difficult to maintain an optimal acoustic window during cycle ergometer exercise tests. The aim herein, is to assess the feasibility of probe fixation for use during exercise echocardiography. METHODS: Forty-eight subjects (47 men, mean age 42 ± 17 years, 25 healthy volunteers, 23 patients with suspected coronary artery disease) were included in this study. All subjects underwent exercise stress test on treadmill (32 cases) or cycle ergometer (16 cases). Both sector and matrix probes were used (in 17 and 31 tests, respectively). The semi-quantitative quality of acquired apical views were assessed at each stage using a four-point grading system. RESULTS: The mean time required for probe fixation was 9 ± 2 min. At baseline, 10 patients had at least one apical window of quality precluding reliable analysis. Twenty-five patients required probe repositioning during exercise (more often on a treadmill). During peak exercise quality of images in all views declined, but for diagnostic purposes it remained sufficient in 29 patients. Thus, 76% of performed tests (60% study population) had sufficient image quality. CONCLUSIONS: Probe fixation offers the possibility of continuous acquisition of echocardiographic images during physical exercise. The device is suitable almost exclusively for male patients and in some patients requires repositioning.
No takes yet. Share an insight, caveat, or question.
Wdowiak‐Okrojek et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: