Key result
Continuous monitoring treadmill exercise echocardiography using a novel ultrasound probe was feasible in 83% of patients and detected coronary artery disease with 61% sensitivity, 100% specificity, and 77% accuracy.
Why the study?
Does a novel ultrasound transducer attached to the chest wall provide feasible continuous monitoring of LV wall motion during treadmill exercise echocardiography to assess coronary artery disease?
Observational (n=36)
No
Does a novel ultrasound transducer attached to the chest wall provide feasible continuous monitoring of LV wall motion during treadmill exercise echocardiography to assess coronary artery disease?
A novel chest-wall attached ultrasound probe enables feasible continuous monitoring of LV wall motion during treadmill exercise echocardiography for the assessment of CAD.
Answers are grounded in this paper and cite their sources.
Supports further development of continuous monitoring during exercise echocardiography; leaves open its clinical role in CAD assessment pending validation studies.
BACKGROUND: The feasibility of a novel ultrasound probe, which can be attached to the left ventricular (LV) apex chest wall and allows free rotation around its long axis direction for the continuous monitoring of LV wall motion, was tested. METHODS AND RESULTS: There were 36 subjects who had coronary artery disease (CAD). By attaching a novel ultrasound probe to the chest wall, the LV apical views were recorded during treadmill exercise stress echocardiography (Echo). The continuous monitoring of LV wall motion was satisfactorily feasible in 30 of 36 patients. The visualization rate of the overall LV segments was higher at rest (90%) compared to that during peak exercise (77%). The segments were better visualized in apical portions (90-100%) than in mid (77-96%) or basal portions (68-87%). The sensitivity, specificity, and accuracy for detecting CAD were 61, 100 and 77%, respectively. The wall motion score index 3 and 6 min after exercise decreased significantly compared to those at peak exercise. The number of segments with dyssynergy was highest at the peak exercise. Ischemic ST-T depression on electrocardiography was observed only at peak stress periods. CONCLUSIONS: Continuous monitoring treadmill exercise Echo using a novel ultrasound probe seems feasible for the non-invasive and physiological assessment of CAD.
No takes yet. Share an insight, caveat, or question.
Nakashiki et al. (2006) conducted an observational in Coronary artery disease (n=36). Continuous monitoring treadmill exercise echocardiography using a novel ultrasound probe vs. Coronary angiography was evaluated on Diagnostic accuracy for detecting coronary artery disease. Continuous monitoring treadmill exercise echocardiography using a novel ultrasound probe was feasible in 83% of patients and detected coronary artery disease with 61% sensitivity, 100% specificity, and 77% accuracy.
Synapse has enriched 10 related papers. Consider them for comparative context: