Answers are grounded in this paper and cite their sources.
Conventional single-phase H-bridge applications have second-order harmonic ripple power on the dc bus. The second-order harmonic power is usually filtered by a bulk capacitor on the dc bus to maintain a constant dc-bus voltage, which results in low power density. However, in applications like VAr generator, a larger dc-bus voltage fluctuation is acceptable since the dc bus connects to no load. This paper releases the constraints on dc-bus voltage fluctuation so that the dc-bus capacitor can be fully utilized. Based on this idea, an H-bridge-based single-phase VAr generator with minimum dc capacitance is proposed, which reduces the dc-bus capacitor to 1/10th of the size compared to that of the sinusoidal pulse width modulation (SPWM)-modulated H-bridge inverter, without increasing components' count. A general modulation method of the proposed VAr generator is derived to utilize the fluctuating dc-bus voltage. The system volume and power loss are assessed to compare with the conventional SPWM-modulated H-bridge and the circuits with power-decoupling cells. A proportional-integral controller is applied to the system to control the input ac current. The analysis and design are validated by simulations and experiments.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: