A personal reflection on 10 years of TAVI experience, detailing the evolution of procedural techniques, imaging, and the shift toward minimalist approaches.
Albert Markus Kasel discusses ten years of TAVI experience When Andreas Grüntzig performed the first-in-man balloon angioplasty in 1977 in Zurich1 some people doubted or even rejected the idea, but certainly no one believed or even imagined that we would perform very straightforward and standardized percutaneous coronary interventions as we do today, often in an ambulatory setting. In 2002, Alain Cribier performed the first-in-man transcatheter aortic valve implantation (TAVI) in Rouen – France, via trans-septal access using a 24-Fr Sheath.2 This achievement is considered, beyond doubt, a turning point for structural heart disease interventions in general and brought hope for high-risk patients with calcific aortic stenosis rejected for surgical valve replacement (SVR). On the 10th anniversary of my first TAVI, I share my modest personal experience along with some insights on future perspectives of this technique and how it may change in the next 10 years. Starting from a cardiovascular imaging background and being the sports physician for the German National Ice-Hockey Team, I changed the focus of my clinical and academic interest. So, my journey towards interventional cardiology began, reaching my current position: a total dedication to structural heart interventions. Munich, April 2010: Together with Prof. Alain Cribier after my first Edwards Sapien proctored cases. My first TAVI implantation was performed in Autumn 2007, as part of the interventional team in the Klinikum Munich-Bogenhausen, Teaching Hospital of the Technical University Munich. It was performed using the self-expanding CoreValve system. In that particular case, things didn't work out as we expected, or at least, as we preferred. The transcatheter valve embolized into the ascending aorta after a post-dilatation attempt where the valve was pulled back with the balloon because the wire re-crossing was probably under the valve struts; a tragic case ending with the proctor fainting and losing consciousness. Our team had to take care of both the proctor and the patient who was sent to surgery. Not the best start for sure, but that's exactly how my story with TAVI began. I am happy to report better outcomes after more than 1500 TAVI cases performed over the last 10 years. Our experience has grown rapidly and we shifted from general anaesthesia to more minimalistic procedures with only conscious sedation after the first 10 cases. Minimalistic TAVI was a radical idea and was only adopted by a handful of leading centres at that time. It then started to spread—largely in Europe—over the years and is currently becoming more and more accepted in the United States (US). Our TAVI understanding evolved with every case and we started to explore different devices including balloon-expandable valves. At that stage, annular measurement and sizing of the device was mainly based on echocardiography. In this regard, we wrote one of the first papers advocating the use of computed tomography (CT) as a standardized tool for TAVI sizing3,4; CT-sizing is now considered the gold standard. Profiting from our growing experience and the relatively high number of procedures, I was progressively involved in physician education and proctoring from 201. Starting in Germany and Europe, going on to South America, Japan and ending in the US where I was the first Proctor for Edwards Lifesciences in November 2011. I had the honour of visiting/proctoring around half of the TAVI centres currently established in the US; more than 100 of the operators also visited our centre at the German Heart Centre in Munich for live-case training. Albert M Kasel left with Dr. Adam Greenbaum right and the first transcaval TAVI patient in Europe, centre. Munich, December 2014. With the immense technical improvement in transcatheter heart valve (THV) and delivery system technology, operator skill, in addition to tips and tricks for more reproducible and predictable results is needed to obtain the best results in TAVI. In 2011, I moved to the German Heart Centre in Munich, where my academic activities have been primarily directed toward this topic. Structural Heart Team, Department of Cardiology, German Heart Center. Munich, April 2017. Beginning with the ‘Follow the Right Cusp’ rule, I described a simplified, useful and reproducible tool that allows proper fluoroscopy-guided aortic root alignment5; a skill that was sometimes challenging and time- and contrast-consuming. This paper was followed by many other tool and technique concepts—thematically titled the ‘Right Cusp Rules’—in addition to other ‘how-to-do’ papers.6 Taken together these publications describe a simplified approach to the procedural steps involved in TAVI and include; Fluoroscopic calcification-guided optimal deployment projection during transcatheter aortic valve replacement—‘The eye of the pigtail.’ (Follow the right cusp rule—Part II).7 Anatomic guided crossing of a stenotic aortic valve under fluoroscopy: ‘right cusp rule, part III’.8 Fluoroscopic balloon sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR)—follow the ‘right cusp rule’.9 Overexpansion of the SAPIEN 3 THV.10 TAVI in Bicuspid Aortic Valves ‘Made Easy’.11 In addition, we performed many innovative interventions in our transcatheter structural program, including the first in Europe transcaval access TAVI12—a technique that became our primary alternative approach to trans-femoral when the arterial access is inconvenient. Interestingly, for the first time, we performed TAVIs for an octogenarian diamond couple on the same day,13 which reflects how TAVI is now accepted as a safe and efficient standard of care from both the operator and the patients’ perspectives. Transcatheter aortic valve implantation is currently considered the gold standard for inoperable and high-risk patients and at least a valid alternative in patients with lower risk. In this regard, I was very happy to offer this treatment to my own former Chief of Department. He was considered a low surgical risk candidate, but, surprisingly, was referred to us by his cardiovascular surgeon who considered TAVI a better treatment strategy than SVR. The intervention was smooth and straightforward, and he returned quickly to his private practice that he is still maintaining. My vision for the future of TAVI is that it becomes a simple, minimalist and reproducible intervention performed safely in a cath-lab setting, extending this treatment modality to low- and even no-risk populations. I look forward to the coming decade and addressing this challenge. Partial View of the Olympic Park in Munich, constructed for the 1972 Summer Olympics. Photo courtesy of Dr. Amr El-Shafei, an interventional cardiologist from the United States who participated in our Live-cases TAVI training program in April 2017. Conflict of interest: none declared. References are available as supplementary material at European Heart Journal online.
No takes yet. Share an insight, caveat, or question.
Albert Markus Kasel (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: