Why the study?
Does two-dimensional Doppler echocardiography accurately measure volume flow across the tricuspid valve compared to invasive methods in dogs and children?
Does two-dimensional Doppler echocardiography accurately measure volume flow across the tricuspid valve compared to invasive methods in dogs and children?
Two-dimensional Doppler echocardiography provides a noninvasive and accurate method for estimating volume flow across the tricuspid valve.
Answers are grounded in this paper and cite their sources.
Supports noninvasive tricuspid flow estimation in children; leaves open larger validation against invasive standards.
In this study we tested a two-dimensional Doppler echocardiographic method for measuring volume flow across the tricuspid valve. Five anesthetized, open-chest dogs had a calibrated electromagnetic flow probe placed on the ascending aorta. Volume flow across the tricuspid valve was controlled by creating a variable femoral-to-pulmonary arterial shunt. Since no standard plane provided a direct view of the tricuspid valve orifice, tricuspid flow area was estimated by calculating a fixed circular flow orifice from the maximal late diastolic diameter of the tricuspid anulus in a four-chamber view. Doppler-determined velocities across the tricuspid valve and tricuspid anulus images in the four-chamber view were obtained in inspiration and expiration. For 24 cardiac outputs (0.6 to 4.0 liters/min), inspiratory tricuspid flow determined by the Doppler method correlated minimally better (r = .90, SEE = 0.30 liter/min) than did expiratory measurements (r = .89, SEE = 0.35 liter/min) with the time-averaged systemic flow determined electromagnetically. Doppler-determined tricuspid volume flows in four-chamber and short-axis two-dimensional echocardiographic views from 10 children were then compared with values determined simultaneously by thermodilution during cardiac catheterization. In the children, Doppler-determined flows in short-axis and four-chamber views, both in inspiration and expiration, were similar; when results for the two views were averaged in inspiration and expiration, the tricuspid flows predicted by the Doppler method were highly correlated (r = .98, SEE = 0.48 liter/min) with the results of thermodilution. The two-dimensional Doppler echocardiographic method provides a means of estimating volume flow across the tricuspid valve noninvasively.
No takes yet. Share an insight, caveat, or question.
Meijboom et al. (1985) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: