Key result
The photonic microsystem achieved a limit of detection of 2 µm (five times lower than video imaging-based myographs) and enabled the analysis of intact arteries in vivo while preserving surrounding tissue integrity.
Why the study?
Early diagnosis of cardiovascular diseases requires ultrasensitive tools to detect minor structural and functional alterations in small arteries, but traditional video imaging-based myographs face limitations in performance, cost, and tissue manipulation.
Answers are grounded in this paper and cite their sources.
A novel PDMS-based photonic microsystem enables highly sensitive, sub-micrometric real-time monitoring of arterial oscillations in intact small arteries in vivo, outperforming traditional video myographs.
Cardiovascular diseases are the first cause of death globally. Their early diagnosis requires ultrasensitive tools enabling the detection of minor structural and functional alterations in small arteries. Such analyses have been traditionally performed with video imaging-based myographs, which helped to investigate the pathophysiology of the microvessels. Since new vascular questions have emerged, substantial modifications are necessary to improve the performance of imaging and tracking software, reducing the cost and minimizing the microvessel cleaning and manipulation. To address these limitations, we present a photonic microsystem fabricated in polydimethylsiloxane and integrating micro-optical elements and a lightguide-cantilever for sub-micrometric analysis of small arteries (between 125 and 400 µm of basal diameter). This technology enables simultaneous measurement of arterial distension, stiffness, vasomotion and heartbeat and without the need for advanced imaging system. The microsystem has a limit of detection of 2 µm, 5 times lower than video imaging-based myographs, is two times more sensitive than them (0.5 µm/mmHg), reduces variability to half and doubles the linear range reported in these myographs. More importantly, it allows the analysis of intact arteries preserving the integrity and function of surrounding tissues. Assays can be conducted in three configurations according to the surrounding tissue: i) isolated arteries (in vitro) where the surrounding tissue is partially removed, ii) non-isolated arteries (in vivo) with surrounding tissue partially removed and iii) intact arteries in vivo preserving surrounding tissue as well as function and integrity. This technology represents a step forward in the prediction of cardiovascular risk.
No takes yet. Share an insight, caveat, or question.
Rodríguez‐Rodríguez et al. (2019) studied Small artery structural and functional alterations. Photonic microsystem (optical myography) vs. Video imaging-based pressure myography was evaluated on Limit of detection for arterial diameter changes. The photonic microsystem achieved a limit of detection of 2 µm (five times lower than video imaging-based myographs) and enabled the analysis of intact arteries in vivo while preserving surrounding tissue integrity.
Synapse has enriched 10 related papers. Consider them for comparative context: