Key result
Combined RF ablation and balloon dilation achieves ~100% interatrial fenestration patency and improves walk distance.
Why the study?
Preclinical research suggested that combined radiofrequency ablation and balloon dilation (CURB) could create stable interatrial communications without device implantation, prompting first-in-human evaluation in severe PAH.
Does modified atrial septostomy combining radiofrequency ablation and balloon dilation (CURB) create stable interatrial communications and improve functional capacity in patients with severe pulmonary arterial hypertension?
Does modified atrial septostomy combining radiofrequency ablation and balloon dilation (CURB) create stable interatrial communications and improve functional capacity in patients with severe pulmonary arterial hypertension?
Answers are grounded in this paper and cite their sources.
The first in-human use of combined radiofrequency ablation and balloon dilation for atrial septostomy in severe PAH demonstrated stable fenestrations and improved functional capacity at mid-term follow-up.
Objective Preclinical research suggests that the combined use of radiofrequency ablation and balloon dilation (CURB) could create stable interatrial communications without device implantation. This study examined the first in-human use of CURB for modified atrial septostomy in patients with severe pulmonary arterial hypertension (PAH). Methods Between July 2018 and October 2021, CURB was performed in 19 patients with severe PAH (age: 31.5±9.1 years; mean pulmonary artery pressure: 73 mm Hg (IQR: 66–92); pulmonary vascular resistance: 18.7 Wood units (IQR: 17.8–23.3)). Under guidance of intracardiac echocardiography and three-dimensional location system, (1) fossae ovalis was reconstructed and ablated point-by-point with radiofrequency; (2) then graded balloon dilation was performed after transseptal puncture and the optimal size was determined according to the level of arterial oxygen saturation (SatO 2 ); (3) radiofrequency ablation was repeated around the rims of the created fenestration. The interatrial fenestrations were followed-up serially. Results After CURB, the immediate fenestration size was 4.4 mm (IQR: 4.1–5.1) with intracardiac echocardiography, systolic aortic pressure increased by 10.2±6.9 mm Hg, cardiac index increased by 0.7±0.3 L/min/m 2 and room-air resting SatO2 decreased by 6.2±1.9% (p<0.001). One patient experienced increased pericardiac effusion postoperatively; the others had no complications. On follow-up (median: 15.5 months), all interatrial communications were patent with stable size (intraclass correlation coefficient=0.96, 95%CI:0.89 to 0.99). The WHO functional class increased by 1 (IQR: 1–2) (p<0.001) with improvement of exercise capacity (+159.5 m, P<0.001). Conclusion The interatrial communications created with CURB in patients with severe PAH were stable and the mid-term outcomes were satisfactory. Trial registration number NCT03554330 .
No takes yet. Share an insight, caveat, or question.
Yan et al. (2022) studied Severe pulmonary arterial hypertension (n=19). Modified atrial septostomy with combined use of radiofrequency ablation and balloon dilation (CURB) vs. Baseline (pre-CURB) was evaluated on Stability and patency of the created interatrial fenestration across follow-up (ICC 0.96, 95% CI 0.89-0.99). Combined radiofrequency ablation and balloon dilation created 100% patent, stable interatrial communications and improved walking distance by 159.5 m.
Synapse has enriched 10 related papers. Consider them for comparative context: