Key result
IntraCycle motion correction is linked to ~16-point higher coronary assessability in high heart rate patients.
Observational (n=120)
Answers are grounded in this paper and cite their sources.
AIMS: Motion artefacts due to high or irregular heart rate (HR) are common limitations of coronary computed tomography (CT) angiography (CCTA). The aim of the study was to evaluate the impact of a new motion-correction (MC) algorithm used in conjunction with low-dose prospective ECG-triggering CCTA on motion artefacts, image quality, and coronary assessability. METHODS AND RESULTS: Among 380 patients undergoing CCTA for suspected CAD, we selected 120 patients with pre-scanning HR >70 bpm or HR variability (HRv) >10 bpm during scanning irrespective of pre-scanning HR or both conditions. In patients with pre-scanning HR <65 or ≥65 bpm, prospective ECG triggering with padding of 80 ms (58 cases) or padding of 200 ms (62 cases) was used, respectively. Mean pre-scanning HR and HRv were 70 ± 7 and 10.9 ± 4 bpm, respectively. Overall, the mean effective dose was 3.4 ± 1.3 mSv, while a lower dose (2.4 ± 0.9 mSv) was measured for padding of 80 ms. In a segment-based analysis, coronary assessability was significantly higher (P < 0.0001) with MC (97%) when compared with standard (STD) reconstruction (81%) due to a significant reduction (P < 0.0001) in severe artefacts (54 vs. 356 cases, respectively). An artefact sub-analysis showed significantly lower number of motion artefacts and artefacts related to chest movement with MC (16 and 4 cases) than with STD reconstruction (286 and 24 cases, P < 0.0001 and P < 0.05, respectively). The number of coronary segments ranked among those of excellent image quality was significantly higher with MC (P < 0.001). CONCLUSIONS: The MC algorithm improves CCTA image quality and coronary assessability in patients with high HR and HRv, despite low radiation dose.
No takes yet. Share an insight, caveat, or question.
Andreini et al. (2015) conducted an observational in Suspected coronary artery disease with high heart rate or heart rate variability (n=120). IntraCycle motion-correction (MC) algorithm with low-dose prospective ECG-triggering CCTA vs. Standard (STD) reconstruction was evaluated on Segment-based coronary assessability (p=<0.0001). The IntraCycle motion-correction algorithm increased segment-based coronary assessability compared with standard reconstruction in high HR/HRv patients.
Synapse has enriched 10 related papers. Consider them for comparative context: