Key result
Automated echocardiographic techniques showed better correlation with MRI-derived ejection fraction (R=0.7 and 0.6 vs 0.4) and higher repeatability (ICC>0.85) than manual methods in HLHS.
Why the study?
Does automated echocardiographic measurement of fractional area change improve repeatability and correlation with MRI-derived ejection fraction compared to manual measurement in children with hypoplastic left heart syndrome?
Cross-Sectional (n=51)
Does automated echocardiographic measurement of fractional area change improve repeatability and correlation with MRI-derived ejection fraction compared to manual measurement in children with hypoplastic left heart syndrome?
p-value: p=<.001
Automated echocardiographic software improves the repeatability of fractional area change measurements and correlates better with MRI-derived ejection fraction than manual methods in children with hypoplastic left heart syndrome.
May support automated EF assessment in HLHS; leaves open prospective validation before clinical adoption.
BACKGROUND: Quantitative echocardiographic assessment of right ventricular function is important in children with hypoplastic left heart syndrome (HLHS). The aim of this study was to examine the repeatability of different echocardiographic techniques, both manual and automated, to measure fractional area change (FAC) in patients with HLHS and to correlate these measurements with magnetic resonance imaging (MRI)-derived ejection fraction (EF). METHODS: Fifty-one children with HLHS underwent transthoracic echocardiography and cardiac MRI under the same general anesthetic as part of routine inter-stage assessment. FAC was measured from the apical four-chamber view using three different techniques: velocity vector imaging (VVI) (Syngo USWP 3.0; Siemens Healthineers), QLAB (Q-lab R 10.0; Philips Healthcare), and manual endocardial contour tracing (Xcelera, Philips Healthcare). Intra- and inter-observer variability was calculated using intra-class correlation coefficient (ICC). FAC was correlated with MRI EF calculated using a single standard method. RESULTS: Fractional area change had a good correlation with MRI-derived EF with an R value for VVI, QLAB, and manual methods of .7, .6, and .4, respectively. Intra- and inter-observer variability for FAC was good for automated echocardiographic methods (ICC>.85) but worse for manual method particularly inter-observer variability of FAC and end-systolic area. Both automated techniques tended to produce higher FAC values compared with manual measurements (P<.001). CONCLUSION: Automation improves the repeatability of FAC in HLHS. There are some differences between automated software in terms of correlation with MRI-derived EF. Measurement bias and wide limits of agreement mean that the same echocardiographic technique should be used during the follow-up of individual patients.
No takes yet. Share an insight, caveat, or question.
Ruotsalainen et al. (2017) conducted a cross-sectional in Hypoplastic left heart syndrome (n=51). Automated echocardiographic techniques (VVI and QLAB) vs. Manual endocardial contour tracing was evaluated on Correlation of fractional area change with MRI-derived ejection fraction (p=<.001). Automated echocardiographic techniques showed better correlation with MRI-derived ejection fraction (R=0.7 and 0.6 vs 0.4) and higher repeatability (ICC>0.85) than manual methods in HLHS.