Answers are grounded in this paper and cite their sources.
X-Ray Imaging and Spectroscopy Mission (XRISM) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the charge-coupled device (CCD) camera, Xtend. Xtend consists of the mirror assembly (X-ray Mirror Assembly) and detector, Soft X-ray Imager (SXI). The SXI is composed of CCDs, analog and digital electronics, and a mechanical cooler. After the successful launch on September 6, 2023 (UT) and subsequent critical operations, the mission instruments were turned on and set up. The CCDs have been kept at the designed operating temperature of −110°C after the electronics and cooling system were successfully set up. During the initial operation phase, which continued for more than a month after the critical operations, we verified the observation procedure, stability of the cooling system, all the observation options with different imaging areas and/or timing resolutions, and time-tagged and automated operations, including those for South Atlantic Anomaly passages. We optimized the operation procedure and observation parameters, including the cooler settings, imaging areas for the small window modes, and the event selection algorithm. We summarize our policy and procedure of the initial operations for the SXI. We also report on a couple of issues we faced during the initial operations and lessons learned from them.
No takes yet. Share an insight, caveat, or question.
Suzuki et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: