Key result
Off-pump coronary artery bypass grafting may increase postoperative hypercoagulability risk compared to on-pump surgery due to normal platelet function and less fibrinolytic activity.
Why the study?
Does off-pump coronary artery bypass grafting alter inflammatory and hemostatic activation compared to on-pump grafting in patients undergoing coronary revascularization?
Observational (n=39)
Does off-pump coronary artery bypass grafting alter inflammatory and hemostatic activation compared to on-pump grafting in patients undergoing coronary revascularization?
Off-pump CABG is associated with less platelet and leukocyte activation but may increase the risk of postoperative hypercoagulability due to preserved platelet function and reduced fibrinolytic activity compared to on-pump CABG.
May warrant thrombosis vigilance after off-pump CABG; leaves open confirmation in randomized trials.
To characterize hemostatic differences imposed by 2 common cardiac surgeries, the authors studied patients undergoing coronary artery revascularization by off-pump (n = 13) or cardiopulmonary bypass on-pump (n = 26) technique. Blood samples collected to 4 days post-surgery were evaluated by flow cytometry and enzyme-linked immunosorbent assay. A significant inflammatory response occurred in both the groups after surgery shown by increased interleukin cytokines and C-reactive protein; however, levels peaked lower and hours later in the off-pump group. Platelets (P-selectin; platelet-leukocyte complexes) and leukocytes (CD11b) were activated only in on-pump patients. Thrombin generation was enhanced in both groups after surgery. Only in the on-pump patients, the thrombin-antithrombin complex, pro-thrombin fragment 1.2, and thrombomodulin (vascular integrity) decreased intraoperatively. Tissue plasminogen activator and plasminogen activator inhibitor-1 were greater in the on-pump patients. Off-pump surgery may place patients at higher risk of postoperative hypercoagulability because of normal platelet function, intraoperative thrombin generation, less fibrinolytic activity, and lack of vascular protection.
No takes yet. Share an insight, caveat, or question.
Untch et al. (2007) conducted an observational in Coronary artery disease requiring revascularization (n=39). Off-pump coronary artery bypass grafting vs. Cardiopulmonary bypass on-pump technique was evaluated on Hemostatic and inflammatory activation markers. Off-pump coronary artery bypass grafting may increase postoperative hypercoagulability risk compared to on-pump surgery due to normal platelet function and less fibrinolytic activity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: