Key result
Circulating IGFBP-7 shows moderate diagnostic performance for OSA and declines after multilevel sleep surgery.
Why the study?
Polysomnography for diagnosing OSA is limited by cost and accessibility, prompting the need for reliable circulating biomarkers to facilitate disease diagnosis and treatment monitoring.
Does multilevel sleep surgery reduce circulating IGFBP-7 levels and apnea-hypopnea index in patients with obstructive sleep apnea?
Cohort (n=164)
No
Does multilevel sleep surgery reduce circulating IGFBP-7 levels and apnea-hypopnea index in patients with obstructive sleep apnea?
Effect estimate: AUC 0.722 (95% CI 0.636-0.808)
p-value: p=<0.001
Circulating IGFBP-7 is elevated in obstructive sleep apnea, correlates with disease severity, and decreases after surgical treatment, suggesting potential utility as a biomarker.
IGFBP-7 may track OSA severity and surgical response; leaves open diagnostic utility pending prospective validation.
Background/Objectives: Obstructive sleep apnea (OSA) is a sleep condition characterized by intermittent hypoxia, systemic inflammation, and metabolic dysfunction. Contemporary diagnosis criteria depend on polysomnography (PSG), a procedure that is limited by cost and accessibility. Identifying reliable circulating biomarkers may facilitate disease diagnosis and treatment monitoring. Methods: Insulin-like growth factor binding protein-7 (IGFBP-7) has been implicated in pathways relevant to OSA, although its precise role remains elusive. While we previously identified IGFBP-7 as a candidate of interest, in this report, we assessed circulating IGFBP-7 levels in a single-cohort study of 164 participants (124 with OSA, 40 controls) at the Dasman Diabetes Institute. A Type I PSG test was performed in a level 1 sleep laboratory to diagnose sleep apnea. Among the 124 patients with OSA who underwent multilevel sleep surgery (MLS), 67 completed the 3-month postoperative follow-up and were included in the longitudinal analyses. In these participants, we evaluated the apnea–hypopnea index (AHI) at baseline and 3 months after surgery and examined the associations between circulating IGFBP-7 levels, OSA severity indices, and metabolic parameters. Results: Our data revealed a significant increase in IGFBP-7 levels in people with OSA compared to controls (p < 0.001). Importantly, the increase in IGFBP-7 was positively correlated with AHI (r = 0.272, p < 0.001), indicating a potential link with this condition. IGFBP-7 levels declined significantly following MLS (p < 0.001), paralleling improvements in AHI and suggesting responsiveness to therapeutic intervention and a reduced hypoxic burden. IGFBP-4 levels increased significantly in patients with OSA (p = 0.006) but were not correlated with IGFBP-7. The receiver operating characteristic (ROC) analysis identified IGFBP-7 with a cut-off value of 14,003.21 pg/mL as a potential biomarker for OSA, with moderate performance (AUC = 0.722, 95% CI: 0.636–0.808; sensitivity 73%, specificity 84%). Notably, combining IGFBP-7 with IGFBP-4 resulted in a modest improvement (AUC = 0.755). Conclusions: Our data suggest that IGFBP-7 shows a modest association with OSA severity and may have exploratory value as part of a multi-marker or risk-stratification approach. Further large-scale and longitudinal studies are warranted to extensively explore the potential utility of IGFBP-7 within multi-marker approaches.
No takes yet. Share an insight, caveat, or question.
Alterki et al. (2026) conducted a cohort in Obstructive sleep apnea (n=164). Circulating IGFBP-7 vs. Controls was evaluated on Diagnostic performance for obstructive sleep apnea (AUC 0.722, 95% CI 0.636-0.808, p=<0.001). Circulating IGFBP-7 levels were significantly elevated in obstructive sleep apnea compared to controls and demonstrated moderate diagnostic performance (AUC 0.722; 95% CI 0.636-0.808).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: