Why the study?
False lumen status predicts late-dissection-related deaths in aortic dissection, prompting evaluation of non-invasive impedance cardiography to monitor false lumen thrombosis.
Can impedance cardiography detect false lumen thrombosis in type B aortic dissection based on multiphysics simulations?
Can impedance cardiography detect false lumen thrombosis in type B aortic dissection based on multiphysics simulations?
Multiphysics simulations suggest that impedance cardiography could be a viable non-invasive method for monitoring false lumen thrombosis in patients with type B aortic dissection.
ICG signal morphology changes with false lumen thrombosis; simulation findings leave open whether serial monitoring can track progression in type B dissection.
Aortic dissection is caused by a tear on the aortic wall that allows blood to flow through the wall layers. Usually, this tear involves the intimal and partly the medial layer of the aortic wall. As a result, a new false lumen develops besides the original aorta, denoted then as the true lumen. The local hemodynamic conditions such as flow disturbances, recirculations and low wall shear stress may cause thrombus formation and growth in the false lumen. Since the false lumen status is a significant predictor for late-dissection-related deaths, it is of great importance in the medical management of patients with aortic dissection. The hemodynamic changes in the aorta also alter the electrical conductivity of blood. Since the blood is much more conductive than other tissues in the body, such changes can be identified with non-invasive methods such as impedance cardiography. Therefore, in this study, the capability of impedance cardiography in monitoring thrombosis in the false lumen is studied by multiphysics simulations to assist clinicians in the medical management of patients under treatment. To tackle this problem, a 3D computational fluid dynamics simulation has been set up to model thrombosis in the false lumen and its impact on the blood flow-induced conductivity changes. The electrical conductivity changes of blood have been assigned as material properties of the blood-filled aorta in a 3D finite element electric simulation model to investigate the impact of conductivity changes on the measured impedance from the body's surface. The results show remarkable changes in the electrical conductivity distribution in the measurement region due to thrombosis in the false lumen, which significantly impacts the morphology of the impedance cardiogram. Thus, frequent monitoring of impedance cardiography signals may allow tracking the thrombus formation and growth in the false lumen.
No takes yet. Share an insight, caveat, or question.
Badeli et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: