This article proposes an approach for realizing the power delivery scheme for an extreme fast charging (XFC) station that is meant to simultaneously charge multiple electric vehicles (EVs). A cascaded H-bridge converter is utilized to directly interface with the medium voltage grid while dual-active-bridge based soft-switched solid-state transformers are used to achieve galvanic isolation. The proposed approach eliminates redundant power conversion by making use of partial power rated dc-dc converters to charge the individual EVs. Partial power processing enables independent charging control over each EV, while processing only a fraction of the total battery charging power. Practical implementation schemes for the partial power charger unit are analyzed. A phase-shifted full-bridge converter-based charger is proposed. Design and control considerations for enabling multiple charging points are elucidated. Experimental results from a down-scaled laboratory test-bed are provided to validate the control aspects, functionality, and effectiveness of the proposed XFC station power delivery scheme. With a down-scaled partial power converter that is rated to handle only 27% of the battery power, an efficiency improvement of 0.6% at full-load and 1.6% at 50% load is demonstrated.
No takes yet. Share an insight, caveat, or question.
Iyer et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: