Key result
Inactivated hepatitis A vaccine demonstrates 100% seroconversion in VAD-supported heart transplant candidates.
Why the study?
Guidelines recommend inactivated hepatitis A virus vaccine for heart transplant candidates, but data on its immunogenicity and safety in candidates with ventricular assist devices are lacking.
Does inactivated hepatitis A virus vaccination achieve adequate seroconversion in heart transplant candidates supported by ventricular assist devices?
Observational (n=35)
No
Does inactivated hepatitis A virus vaccination achieve adequate seroconversion in heart transplant candidates supported by ventricular assist devices?
Inactivated hepatitis A vaccination is highly immunogenic and safe in heart transplant candidates supported by ventricular assist devices, achieving a 100% seroconversion rate.
Adds retrospective immunogenicity data for HAV vaccine in VAD patients; leaves open prospective validation before routine adoption.
Vaccination is among the cornerstones of infectious disease prevention in heart transplant candidates and recipients. Guidelines recommend an inactivated hepatitis A virus vaccine for heart transplant candidates, many of whom are on ventricular assist devices and at risk of hepatitis A virus exposure. However, data on the immunogenicity and safety of hepatitis A virus vaccines in these patients are lacking.This retrospective, observational, single-center study was conducted at our outpatient clinic between December 2019 and December 2025. The study participants were heart transplant candidates with ventricular assist devices aged ≥16 years who tested negative for anti-hepatitis A virus immunoglobulin G at baseline and completed the inactivated hepatitis A virus vaccination series. Anti-hepatitis A virus immunoglobulin G titers were measured after vaccination using a chemiluminescent immunoassay. Thirty-five individuals were included in the study. Immunosuppressive agents were used in four patients (11.4%). All participants achieved seroconversion at a median of 1 month after vaccination. The reverse cumulative distribution of the Anti-hepatitis A virus immunoglobulin G sample/cutoff values indicated that an adequate antibody response was achieved in individuals with ventricular assist devices. Adverse events of the vaccine were minor; two patients (6%) experienced local pain, and two (6%) subcutaneous hemorrhage. Seroconversion in patients with ventricular assist devices was high. hepatitis A virus vaccination should be completed before transplantation in heart transplant candidates, if indicated.
No takes yet. Share an insight, caveat, or question.
Arima et al. (2026) conducted an observational in Heart transplant candidates with ventricular assist devices (n=35). Inactivated hepatitis A virus vaccine was evaluated on Seroconversion (anti-HAV IgG positivity). Inactivated hepatitis A vaccination achieved a 100% seroconversion rate in heart transplant candidates supported by ventricular assist devices, with only minor adverse events.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: