Key result
Two-dimensional and M-mode echocardiographic measurements in healthy adult Saanen goats demonstrated good inter-day repeatability and yielded reference values similar to those in healthy adult sheep.
Why the study?
What are the reference values and inter-day repeatability of 2D- and M-mode echocardiographic variables in healthy adult Saanen goats?
Observational (n=12)
What are the reference values and inter-day repeatability of 2D- and M-mode echocardiographic variables in healthy adult Saanen goats?
The study establishes reliable 2D- and M-mode echocardiographic reference values for healthy adult Saanen goats, which are comparable to those of adult sheep.
May inform caprine echocardiographic norms; leaves open prospective validation before veterinary clinical use.
Echocardiography has become a routine non-invasive cardiac diagnostic tool in most species. Accurate measurement of cardiac dimensions requires reference values, which are poorly documented in goats. The aim of the present study was to test the inter-day repeatability and to establish the reference values of two-dimensional (2D-) and time-motion (M-) mode echocardiographic variables in healthy adult Saanen goats. Six goats were investigated three times by the same observer at one-day interval using a standardised 2D- and M-mode echocardiographic protocol. The intra-observer inter-day repeatability was tested using analysis of variance, calculation of the coefficient of variation and confidence intervals. A single echocardiographic examination was performed in six other goats, and values obtained in the 12 goats were used to establish the 2D- and M-mode echocardiographic reference values in healthy adult female Saanen goats. Statistical analysis revealed a good inter-day repeatability of the echocardiographic cardiac measurements. Echocardiographic reference values obtained in healthy adult Saanen goats seemed slightly higher than those reported in healthy Swedish domestic goats and were similar to those reported in healthy adult sheep.
No takes yet. Share an insight, caveat, or question.
Leroux et al. (2011) conducted an observational in Healthy (n=12). 2D- and M-mode echocardiography was evaluated on Inter-day repeatability and echocardiographic reference values. Two-dimensional and M-mode echocardiographic measurements in healthy adult Saanen goats demonstrated good inter-day repeatability and yielded reference values similar to those in healthy adult sheep.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: