Key result
The high sensitivity Abbott cardiac troponin I assay demonstrated an area under the curve of 0.92 for diagnosing myocardial infarction on admission, comparable to four other assays.
Why the study?
What are the clinical and diagnostic performance characteristics of the high sensitivity Abbott cardiac troponin I assay for diagnosing myocardial infarction?
Population
Fully characterized population that had undergone non-invasive cardiac imaging and emergency department…
Comparison
High sensitivity Abbott cardiac troponin I assay vs Four other cardiac troponin assays
Design
Cross-sectional
Authors
Loading...
Should not yet alter troponin assay selection; extends cross-sectional evidence on hs-cTnI comparability.
Observational
Yes
What are the clinical and diagnostic performance characteristics of the high sensitivity Abbott cardiac troponin I assay for diagnosing myocardial infarction?
Effect estimate: AUC 0.92
The new high sensitivity Abbott cardiac troponin I assay demonstrates excellent analytical performance and diagnostic accuracy for myocardial infarction, comparable to existing assays.
Collinson et al. (2014) conducted an observational in Myocardial infarction. High sensitivity Abbott cardiac troponin I assay vs. Four other troponin assays was evaluated on Diagnosis of myocardial infarction on admission (AUC 0.92). The high sensitivity Abbott cardiac troponin I assay demonstrated an area under the curve of 0.92 for diagnosing myocardial infarction on admission, comparable to four other assays.