Key result
Immunochromatographic tests for diagnosing norovirus provided low sensitivity but high specificity and a diagnostic.9.
Why the study?
Noroviruses are the leading cause of acute gastroenteritis worldwide, but the diagnostic accuracy of immunochromatographic tests for detecting norovirus in stool specimens had not been previously evaluated in a systematic review and meta-analysis.
Does immunochromatographic testing accurately detect norovirus in stool specimens?
Meta-Analysis (n=7,428)
Does immunochromatographic testing accurately detect norovirus in stool specimens?
Immunochromatographic tests for norovirus have high specificity but low sensitivity, meaning a positive result is reliable but a negative result requires confirmation.
Answers are grounded in this paper and cite their sources.
Low-sensitivity ICTs enable rapid norovirus confirmation but miss many cases; first pooled estimates extend single-study data for test evaluation.
Noroviruses are the leading cause of acute gastroenteritis in all age groups and constitute a major health and economic burden worldwide. This systematic review and meta-analysis aimed to determine the diagnostic accuracy of immunochromatographic tests (ICTs) for the detection of norovirus in stool specimens, which has not been performed previously. In this systematic review and meta-analysis (registered on PROSPERO, CRD42020186911), we searched Medline/PubMed, Embase, Cochrane Library, and Web of Science for all studies published up to 16 May 2020. The values for sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR) of ICTs with 95% confidence interval (CI) were pooled using a bivariate random-effects model. The summary receiver operating characteristic curve and area under the curve were used to summarize overall test accuracy. We included 43 studies describing 7,428 samples. The overall estimates of sensitivity, specificity, LR+, LR-, DOR, and accuracy of ICT for diagnosing norovirus were 0.61 (95% CI, 0.54 to 0.67), 0.97 (95% CI, 0.95 to 0.98), 17.08 (95% CI, 11.15 to 26.18), 0.40 (95% CI, 0.34 to 0.46), 53.9 (95% CI, 31.32 to 92.78), and 0.928, respectively. Significant differences in pooled sensitivities were noted between age groups and in pooled DOR and LR+ between genogroups of included samples. ICT provides low sensitivity but high specificity and accuracy for detecting norovirus. Thus, an ICT for norovirus can be a rapid and convenient way for identifying patients early; however, a negative result cannot rule out norovirus infection and should be confirmed by a reference test.
No takes yet. Share an insight, caveat, or question.
Yoon et al. (2021) conducted a meta-analysis in Norovirus infection (n=7,428). Immunochromatographic tests (ICTs) vs. Reference test was evaluated on Diagnostic accuracy (sensitivity, specificity, likelihood ratios, and diagnostic odds ratio) (DOR 53.9, 95% CI 31.32-92.78). Immunochromatographic tests for diagnosing norovirus provided low sensitivity but high specificity and a diagnostic.9.