Eccentrically Braced Frames (EBFs) are widely used to resist lateral forces, leveraging ductile design principles to reduce seismic demands. However, the current New Zealand Steel Structures Standard (NZS 3404) provides limited guidance for computing deformation demands, overlooking variability of inelastic behaviour along the frame height and potentially leading to inaccurate seismic performance assessments. The provisions also disregard the contribution of post-yield stiffness by adopting an elastic–perfectly plastic link response, which can underestimate the load-carrying capacity of EBF systems. This study evaluates the seismic performance of multi-storey EBFs through nonlinear pushover analyses of an eight-storey case study, developed using an experimentally validated finite element model. Predictions from design provisions and an alternative analytical method are benchmarked against the nonlinear results, focusing on displacement profiles, storey drift demands, link rotations, and the influence of base rotational stiffness, post-yield stiffness, and shear link length. The findings show that while standard methods provide acceptable accuracy in the elastic range, they fail to capture redistribution of plastic demands in the nonlinear regime. The results also demonstrate that parameters such as base rotational restraint and strain-hardening can significantly influence the seismic response of EBF systems, highlighting the need for advanced design methodologies to provide more accurate seismic design.
No takes yet. Share an insight, caveat, or question.
Hasanali et al. (2025) studied this question.