Why the study?
Lead failure is a major complication of ICDs, and mid-to-long term outcomes of pacing sensing lead implantation versus new ICD lead implantation were investigated.
Does pacing sensing lead (PSL) implantation improve outcomes compared to new ICD lead implantation in ICD patients presenting with lead failure?
Does pacing sensing lead (PSL) implantation improve outcomes compared to new ICD lead implantation in ICD patients presenting with lead failure?
Addition of a pacing sensing lead for IS-1/DF-1 ICD lead failure with normal high-voltage conductor measurements is a viable treatment option with similar long-term results to adding a new ICD lead.
PSL addition for ICD LF was associated with comparable outcomes to new lead implantation; leaves open whether it is a durable alternative.
Background Intracardiac defibrillator/cardioverter (ICD) is a cornerstone device for prevention of sudden cardiac death. Lead failure (LF) is one of the most important long-term complications. In this study, we sought to investigate mid-to-long term clinical, device and lead characteristics of patients who have undergone pacing sensing lead (PSL) implantation for an ICD LF and compare them to the patients who have undergone a new ICD lead implantation.Methods In this retrospective, single centre, case-control study, we have screened all ICD patients presenting with LF. Patients with IS-1/DF-1 ICD leads with intact high-voltage conductor were included in the study group, while other patients were included in the control arm. Study group patients underwent PSL implantation, control group patients underwent ICD lead implantation.Results Thirty patients were included in each arm of the study. The mean duration of follow-up after intervention was similar in both groups (47.6 months ± 20.4 vs. 46.1 months ± 25.7, p = .808). The total failure rate was not different between two groups (p = .640). Rate of high-voltage conductor disfunction was also similar between two arms: 1 (3.3%) in PSL arm and 0 in control arm (p = .303).Conclusions Addition of a PSL for IS-1/DF-1 ICD LF with normal high-voltage conductor measurements is a viable treatment option with similar long-term results to addition of a new ICD lead. This approach is potentially less costly, technically less demanding, and, in case of concomitant extraction procedure, associated with less acute complication risk.
No takes yet. Share an insight, caveat, or question.
Baskovski et al. (2023) studied this question.