Answers are grounded in this paper and cite their sources.
In this paper, an electric field sensor (EFS) with high sensitivity is proposed for low-frequency weak-strength ac electric field ( E -field) measurements. The EFS is based on a piezoelectric cantilever biased by a strong electrostatic field. The electrostatic bias can enhance the electric field force of a weak ac E -field, thus the cantilever can oscillate in a weak ac E -field and the device sensitivity improves. Theoretical analyses have been established and suggest that a stronger strength of electrostatic field bias would produce a higher sensitivity improvement. In the experiment, a demonstrated sensor consisting of a polyvinylidene fluoride (PVDF) piezoelectric cantilever and a polytetrafluoroethylene (PTFE) electret was built and tested. Instead of extra voltage sources, the PTFE electret was charged to provide the electrostatic field, allowing the EFS a low energy consumption and a simple electric circuit design. The experiment results show good agreement with the simulation. The sensitivity of the cantilever E -field sensor reached 0.84 mV (kV/m) −1 when the surface potential of the electret was −770 V.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: