Key result
COBRA-PzF stents reduce platelet adhesion up to ~84% versus comparator drug-eluting stents in cytokine storms.
Why the study?
Cytokine storm-related hypercoagulation may contribute to stent thrombosis in SARS-CoV-2, but whether stent polymers behave differently under these conditions had not been explored.
Does a fluorinated polymer-nanocoated stent (COBRA-PzF) reduce platelet adhesion and neutrophil activation compared to uncoated COBRA, Resolute Onyx, and Synergy stents under simulated COVID-19 cytokine storm conditions in vitro?
Does a fluorinated polymer-nanocoated stent (COBRA-PzF) reduce platelet adhesion and neutrophil activation compared to uncoated COBRA, Resolute Onyx, and Synergy stents under simulated COVID-19 cytokine storm conditions in vitro?
Under in vitro simulated COVID-19 cytokine storm conditions, fluoropolymer-nanocoated COBRA-PzF stents demonstrated the lowest platelet adhesion and neutrophil activation compared with Resolute Onyx and Synergy drug-eluting stents, generating the hypothesis that stent biomaterial selection may influence thrombotic risk in hyperinflammatory states.
Answers are grounded in this paper and cite their sources.
Fluoropolymer coating may reduce platelet adhesion in cytokine storm; leaves open whether biomaterial choice affects clinical thrombosis risk.
Cytokine storm-related hypercoagulation may be important in the pathogenesis of stent thrombosis in patients with SARS-CoV-2. Whether stent polymers behave differently under such conditions has never been explored. Fluorinated polymer-nanocoated and uncoated COBRA stents (CeloNova), BioLinx-polymer-coated Resolute Onyx stents (Medtronic), and Synergy stents (Boston Scientific), which are abluminally coated with a bioabsorbable polymer, were exposed to human blood from healthy donors which was supplemented with 400 pg/mL IL-6 and 100 pg/mL TNF-α, similar to what is seen in cytokine storm caused by SARS-CoV-2. Platelet adhesion and neutrophil activation, assessed by immunofluorescence, were compared under cytokine storm and control conditions (untreated blood) (n = 4 experimental runs). Platelet adhesion values, defined as %platelet-covered area x staining intensity, were significantly lower in coated and uncoated COBRA and in Resolute Onyx than in Synergy under control conditions (1.28 × 107 ± 0.43 × 107 vs. 2.92 × 107 ± 0.49 × 107 vs. 3.57 × 107 ± 0.73 × 107 vs. 9.94 × 107 ± 0.99 × 107; p ≤0.0001). In cytokine storm, platelet adhesion values remained low in coated COBRA-PzF (1.78 × 107 ± 0.38 × 107) compared to all other devices (uncoated COBRA: 5.92 × 107 ± 0.96 × 107; Resolute Onyx: 7.27 × 107 ± 1.82 × 107; Synergy: 11.28 × 107 ± 1.08 × 107; p ≤ 0.0001). Although cytokine storm conditions significantly increased neutrophil activation in all stents, it was significantly less in coated and uncoated COBRA, and in Resolute Onyx than in Synergy. Blood-biomaterials interactions may determine the thrombogenic potential of stents. Under simulated cytokine storm conditions, fluoropolymer-coated stents showed the most favorable anti-thrombogenic and anti-inflammatory properties.
No takes yet. Share an insight, caveat, or question.
Cornelissen et al. (2021) studied Simulated COVID-19 cytokine storm stent thrombogenicity (n=4). Fluorinated polymer-nanocoated COBRA-PzF stent vs. Uncoated COBRA stent, BioLinx-polymer-coated Resolute Onyx stent, and bioabsorbable-polymer-coated Synergy stent under cytokine storm and untreated blood control conditions was evaluated on Platelet adhesion values (% platelet-covered area x staining intensity) under simulated cytokine storm conditions (p=≤0.0001). Fluoropolymer-coated COBRA-PzF stents had lower platelet adhesion in simulated cytokine storm than uncoated COBRA, Resolute Onyx, and Synergy.
Synapse has enriched 10 related papers. Consider them for comparative context: