Key result
Temporary ventricular overdrive pacing suppresses refractory post-MI electrical storm as an effective bridge to ICD.
Why the study?
Does temporary ventricular overdrive pacing terminate refractory electrical storm and serve as a bridge to ICD implantation in a patient with acute anterior myocardial infarction failing multiple antiarrhythmic medications?
Case Report (n=1)
No
Does temporary ventricular overdrive pacing terminate refractory electrical storm and serve as a bridge to ICD implantation in a patient with acute anterior myocardial infarction failing multiple antiarrhythmic medications?
Temporary ventricular overdrive pacing can serve as an effective bailout therapy for acute hemodynamic and electrical stabilization and as a bridge to ICD implantation in patients with post-myocardial infarction electrical storm refractory to antiarrhythmic drugs and deep sedation.
Answers are grounded in this paper and cite their sources.
May offer bailout stabilization in refractory post-MI storm; leaves open need for prospective validation before adoption.
An electrical storm (ES) is defined as the presence of at least three episodes of sustained ventricular tachycardia or ventricular fibrillation within 24 h. This patient had a previously known arterial hypertension, type II diabetes mellitus, and chronic kidney disease and has presented to the Emergency Department (ED) with symptoms of retrosternal chest pain lasting for several hours prior. The initial 12-lead electrocardiogram revealed ST segment elevation in the anterior leads (V1-V6). Emergent coronary angiography revealed an acute occlusion of the proximal left anterior descending artery (pLAD) and percutaneous coronary intervention was performed with successful implantation of one drug-eluting stent in the pLAD. On day 8 of hospitalization, the patient developed a refractory ES for which he received 50 DC shocks and did not respond to multiple lines of antiarrhythmic medications. Due to a failure of medical therapy, we decided to implant a temporary pacemaker and initiate ventricular overdrive pacing (VOP) that was successful in terminating ES. Following electrical stabilization, the patient underwent a successful ICD implantation. This case demonstrates that VOP can contribute to hemodynamic and electrical stabilization of a patient that suffers from refractory ES and this treatment modality might serve as a temporary bridge to ICD implantation.
No takes yet. Share an insight, caveat, or question.
Meter et al. (2024) conducted a case report in Refractory electrical storm following acute anterior myocardial infarction (n=1). Temporary ventricular overdrive pacing (VOP) was evaluated on Termination of refractory electrical storm and achievement of acute hemodynamic and electrical stability. Temporary ventricular overdrive pacing at 85-90 bpm terminated a drug-refractory electrical storm (>50 DC shocks) after acute MI, serving as a 12-day bridge to ICD implantation.