Key result
Temporary ventricular overdrive pacing successfully terminated refractory electrical storm in a patient after acute myocardial infarction, serving as a bridge to ICD implantation.
Why the study?
Does temporary ventricular overdrive pacing terminate refractory electrical storm in a patient post-acute myocardial infarction?
Case Report (n=1)
Does temporary ventricular overdrive pacing terminate refractory electrical storm in a patient post-acute myocardial infarction?
Temporary ventricular overdrive pacing can serve as an effective bridge to ICD implantation in patients with refractory electrical storm post-myocardial infarction.
Temporary overdrive pacing terminated refractory ES post-MI; leaves open its role versus ablation in larger cohorts.
Electrical storm (ES) is defined as the presence of at least three episodes of sustained ventricular tachycardia or ventricular fibrillation within 24 hours. This patient had a previously known arterial hypertension, type II diabetes mellitus, and chronic kidney disease and has presented to the Emergency Department (ED) with symptoms of retrosternal chest pain lasting for several hours prior. The initial 12-lead electrocardiogram revealed ST segment elevation in the anterior leads (V1-V6). Emergent coronary angiography revealed an acute occlusion of the proximal left anterior descending artery (pLAD) and percutaneous coronary intervention was performed with successful implantation of one drug-eluting stent in the pLAD. On the day 8 of hospitalization, patient developed a refractory ES for which he received 50 DC shocks and did not respond to multiple lines of antiarrhythmic medications. Due to a failure of medical therapy, we decided to implant a temporary pacemaker and initiate ventricular overdrive pacing (VOP) that was successful in terminating ES. Following electrical stabilization, the patient underwent a successful ICD implantation. This case demonstrates that VOP can contribute to hemodynamic and electrical stabilization of a patient that suffers from refractory ES and this treatment modality might serve as a temporary bridge to ICD implantation.
No takes yet. Share an insight, caveat, or question.
Meter et al. (2023) conducted a case report in Refractory electrical storm after acute myocardial infarction (n=1). Temporary ventricular overdrive pacing (VOP) was evaluated on Termination of electrical storm and stabilization. Temporary ventricular overdrive pacing successfully terminated refractory electrical storm in a patient after acute myocardial infarction, serving as a bridge to ICD implantation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: