Experimental study demonstrates high sensitivity and low power consumption in AlGaN/GaN pressure sensors, highlighting viability for integrated harsh-environment electronics.
This study focuses on developing low-power, highly sensitive AlGaN/GaN pressure sensors for harsh environmental conditions, utilizing Au-free fabrication techniques to enable the integration of a readout-circuit on the same chip. For this purpose, a variation of membrane and device design is fabricated in Wheatstone bridge configuration and compared in terms of sensitivity, linearity and hysteresis performance at different pressure levels up to 1060 kPa and temperature conditions between 0 ° C and 100 ° C . The HEMT topology with a bossed membrane is identified as the most effective, offering superior sensitivity, linearity, and minimal hysteresis. The study highlights the novelty of using gated devices in a Wheatstone bridge configuration together with bossed, ring-shaped membranes for sensitivity scaling. The HEMT sensor with a 3 mm diameter ring-shaped membrane shows a peak sensitivity of 336.3 μ V k P a , surpassing previously published results. Additionally, the sensors maintain a low energy consumption of approximately 8.33 mW. • Co-integratable GaN sensor technology for further circuits is shown. • Techniques for sensitivity enhancement by membrane optimization are demonstrated. • HEMTs demonstrate the scalability of sensitivity by modulation of the gate voltage. • Temperature effects on sensor performance are studied up to 100 °C.
No takes yet. Share an insight, caveat, or question.
Moser et al. (2025) studied this question.