Key result
Restoring atrioventricular synchrony using coronary sinus pacing with a Damato multi-polar catheter immediately returned the patient to hemodynamic stability.
Why the study?
The role of atrioventricular dyssynchrony causing low Impella device output in cardiogenic shock from acute anterior MI responding to restored AV synchrony had not been previously reported.
Does coronary sinus pacing to restore AV synchrony improve hemodynamic stability in a patient with cardiogenic shock and low Impella output?
Case Report (n=1)
Does coronary sinus pacing to restore AV synchrony improve hemodynamic stability in a patient with cardiogenic shock and low Impella output?
Restoring AV synchrony via coronary sinus pacing using a Damato multi-polar catheter can immediately stabilize hemodynamics in patients with cardiogenic shock and low Impella output due to AV dyssynchrony.
Answers are grounded in this paper and cite their sources.
May warrant AV optimization during Impella support in anterior MI shock; hypothesis-generating case report requiring prospective validation.
The role of atrioventricular (AV) dyssynchrony as a cause of low Impella device output in cardiogenic shock from acute anterior myocardial infarction (MI) responding to reestablishing AV synchrony has not been previously reported. We present, for the first time, a unique case of AV dyssynchrony causing recurrent hypotension and ventricular fibrillation in such a patient, followed by immediate return to hemodynamic stability after restoring AV synchrony. Our case also highlights the novel use of a Damato multi-polar catheter for coronary sinus pacing to achieve AV synchrony.
No takes yet. Share an insight, caveat, or question.
Tahir et al. (2021) conducted a case report in Cardiogenic shock from acute anterior myocardial infarction with low Impella device output (n=1). Coronary sinus pacing using a Damato multi-polar catheter was evaluated on Hemodynamic stability. Restoring atrioventricular synchrony using coronary sinus pacing with a Damato multi-polar catheter immediately returned the patient to hemodynamic stability.