Why the study?
Can subxiphoid echocardiography accurately measure right ventricular wall thickness and correlate with right ventricular peak systolic pressure in adults?
Can subxiphoid echocardiography accurately measure right ventricular wall thickness and correlate with right ventricular peak systolic pressure in adults?
Subxiphoid echocardiography is a feasible and accurate non-invasive method for measuring right ventricular wall thickness and diagnosing right ventricular hypertrophy in adults.
Answers are grounded in this paper and cite their sources.
Supports subxiphoid RVWT feasibility; cross-sectional data leave prospective validation against catheterization open.
The feasibility of subxiphoid echocardiography to measure the thickness of the right ventricular wall (RVWT) was investigated. In 87 (90.6%) of the 96 patients studied, adequate visualization of the echoes from the right ventricular wall was obtained using the subxiphoid technique. RVWT averaged 0.34 +/- 0.08 cm (mean +/- 1 SD), ranging from 0.2 to 0.5 cm in 25 normal individuals. This was not significantly different from the values in the left ventricular overload group (0.36 +/- 0.10 cm). However, the RVWT was increased significantly (P less than 0.001) in the combined group (0.62 0.18 cm), the right ventricular (RV) pressure overload group (0.60 +/- 0.13 cm) and the RV volume overload group (0.53 +/- 0.11 cm). Thirty-two patients underwent diagnosis right heart catheterization which revealed a good correlation between the RVWT measured echocardiographically and the right ventricular peak systolic pressure (r = 0.84). Subxiphoid echocardiography was considered to be useful in diagnosing right ventricular hypertrophy in adults.
No takes yet. Share an insight, caveat, or question.
Matsukubo et al. (1977) studied this question.