Answers are grounded in this paper and cite their sources.
Due to its voltage-fed nature and a capacitive output filter, the rear-end rectifier of parallel and series-parallel resonant converters with capacitive filters draw discontinuous currents. Not only simple and elegant techniques such as fundamental harmonic approximation (FHA) analysis, but also time-domain, state-space, and state-plane approaches fail to model such converters with reduced labor. This letter presents a technique to restore the simplicity of FHA analysis about such converters. Authenticity and accuracy of the proposed technique is demonstrated through PSIM 11.0 simulation platform. Furthermore, a detailed comparison with the existing modeling techniques is also provided.
No takes yet. Share an insight, caveat, or question.
Rathore et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: