Why the study?
Conventional bipolar electrodes may be suboptimal to detect local abnormal ventricular activities, and whether microelectrodes improve detection in scar-related VT needed elucidation.
Do microelectrodes improve the detection of local abnormal ventricular activities compared to conventional bipolar electrodes in patients with scar-related VT?
Do microelectrodes improve the detection of local abnormal ventricular activities compared to conventional bipolar electrodes in patients with scar-related VT?
Answers are grounded in this paper and cite their sources.
Microelectrodes improve the detection and amplitude of local abnormal ventricular activities in scar-related VT ablation compared to conventional bipolar electrodes, identifying 20% of signals missed by conventional methods.
BACKGROUND: Conventional bipolar electrodes (CBE) may be suboptimal to detect local abnormal ventricular activities (LAVAs). Microelectrodes (ME) may improve the detection of LAVAs. This study sought to elucidate the detectability of LAVAs using ME compared with CBE in patients with scar-related ventricular tachycardia (VT). METHODS: We included consecutive patients with structural heart disease who underwent radiofrequency catheter ablation for scar-related VT using either of the following catheters equipped with ME: QDOTTM or IntellaTip MIFITM. Detection field of LAVA potentials were classified as three types: Type 1 (both CBE and ME detected LAVA), Type 2 (CBE did not detect LAVA while ME did), and Type 3 (CBE detected LAVA while ME did not). RESULTS: In 16 patients (68 ± 16 years; 14 males), 260 LAVAs electrograms (QDOT = 72; MIFI = 188) were analyzed. Type 1, type 2, and type 3 detections were 70.8% (QDOT, 69.4%; MIFI, 71.3%), 20.0% (QDOT, 23.6%; MIFI, 18.6%) and 9.2% (QDOT, 6.9%; MIFI, 10.1%), respectively. The LAVAs amplitudes detected by ME were higher than those detected by CBE in both catheters (QDOT: ME 0.79 ± 0.50 mV vs. CBE 0.41 ± 0.42 mV, p = .001; MIFI: ME 0.73 ± 0.64 mV vs. CBE 0.38 ± 0.36 mV, p < .001). CONCLUSIONS: ME allow to identify 20% of LAVAs missed by CBE. ME showed higher amplitude LAVAs than CBE. However, 9.2% of LAVAs can still be missed by ME.
No takes yet. Share an insight, caveat, or question.
Nakashima et al. (2021) studied this question.