Why the study?
Blood pressure variability independently predicts adverse clinical events in hemodialysis patients, and the effect of dry weight reduction on home blood pressure variability was unknown.
Does gradual dry weight reduction guided by bioimpedance methods improve home blood pressure variability in hemodialysis patients with volume overload?
Does gradual dry weight reduction guided by bioimpedance methods improve home blood pressure variability in hemodialysis patients with volume overload?
Gradual dry weight reduction guided by bioimpedance significantly improves home systolic blood pressure variability in hemodialysis patients with chronic fluid overload.
Dry weight reduction may lower home BP variability in volume-overloaded HD patients; hypothesis-generating and needs randomized confirmation before practice change.
Blood pressure variability is an independent predictor of adverse clinical events in hemodialysis patients. Volume overload is one of the most important factors affecting blood pressure homeostasis. In the present study, we explored the effects of dry weight reduction on home blood pressure variability in volume overload hemodialysis patients. Hemodialysis patients with volume overload had their dry weight gradually decreased under the guidance of bioimpedance methods, which was represented by calf-bioimpedance ratio (Calf-BR). Home blood pressure was measured on waking up and at bedtime for 1 week at baseline and at the end of the two-month study. Coefficient of variation was used to define home blood pressure variability. Thirty-eight hemodialysis patients had their dry weight significantly decreased from 60.7 ± 11.3 to 59.6 ± 10.7 kg (P = 0.003) accompanied with a significant reduction in calf-BR (0.828 ± 0.023 vs. 0.786 ± 0.020, P<0.001). The systolic and diastolic blood pressure decreased significantly. Moreover, the whole-day, morning, and evening systolic blood pressure variability gradually and significantly decreased by the end of the study (5.6 ± 2.1% versus 4.0 ± 1.7%, P<0.001; 7.7 ± 3.5% vs. 6.3 ± 2.7%, P = 0.005; 7.5 ± 2.8% vs. 5.9 ± 2.3%, P = 0.002, respectively). Diastolic blood pressure variability parameters were unchanged. The interdialytic weight gain and the incidence of adverse events were similar throughout the study period. Gradual dry weight reduction by bioimpedance methods improved home blood pressure variability in hemodialysis patients with chronic fluid overload.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: