Why the study?
In hemodialysis patients, 24-hours interdialytic ABPM better detects target organ damage than dialysis unit blood pressure, but its performance for diagnosing ECG-LVH in Black patients required evaluation.
Does 24-hours interdialytic ABPM improve the diagnosis of ECG-LVH compared to dialysis unit blood pressure in chronic hemodialysis black patients?
Does 24-hours interdialytic ABPM improve the diagnosis of ECG-LVH compared to dialysis unit blood pressure in chronic hemodialysis black patients?
24-hour interdialytic ABPM and dialysis unit BP both detect ECG-LVH in chronic hemodialysis patients, with ABPM tending to have the highest diagnostic performance.
Answers are grounded in this paper and cite their sources.
ABPM showed highest diagnostic performance for ECG-LVH; leaves open whether it should replace unit BP monitoring in black HD patients.
Background and Aim: In hemodialysis patients, 24-hours interdialytic ABPM better detects TOD than dialysis unit blood pressure. Therefore, the present study was aimed to assess the diagnostic performance of 24-hours ABPM vs. dialysis unit BPs for the diagnosis of ECG-LVH in steady state chronic hemodialysis black patients. Methods: From March 31 to September 30, 2018, interdialytic ABPM was performed after a mid-week hemodialysis session for 24 hours using a Spacelab 90207 ABPM monitor in the non-access arm in 45 stable chronic hemodialysis black patients (age ≥ 20 years, hemodialysis for at least 3 months and informed consent) attending 3 hemodialysis centers in Kinshasa. Ambulatory BP was recorded every 20 minutes during the day (6 AM to 10 PM) and every 30 minutes during the night (10 PM to 6 AM). ECG-LVH was defined using Cornell product criteria. ROC curve method was used to assess the performance of dialysis unit BPs vs. interdialytic 24-hours ABPM in diagnosing ECG-LVH. P 0.05 defined the level of statistical significance. Results: Whatever the method of BP measurement, all the SBP values were related to ECG-LVH with similar AUC and overlapping 95% CI; however, they were not significantly different from each other. 24-hours interdialytic ambulatory SBP (AUC 0.748; 95% CI 0.58 - 0.94) had the highest area under the curve. Conclusion: The present study showed that although all the two BP measurement methods equally detected ECG-LVH, 24-hours ABPM tended to have the highest diagnostic performance.
No takes yet. Share an insight, caveat, or question.
Ilunga et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: