Experiments have been performed to study convective heat transfer in the entrance region of corrugated channels. With water as the working fluid, two channel spacings were examined for a single corrugation angle of 20°. The flow rate was varied over the range I50 ≤ Re ≤ 4000. Flow visualization under low-Reynolds-number flow conditions suggested the presence of longitudinal vortices, while at somewhat higher Reynolds numbers, the existence of spanwise vortices was clearly revealed. For Re > 1500, Nusselt numbers in the corrugated channels exceeded those in the parallel-plate channel by approximately 140% and 240% for the two channel spacings, the corresponding increases in friction factor being 130% and 280%. Performance evaluations under the criteria of equal mass flow rate, equal pumping power, and equal pressure drop per unit length established both the corrugated channels as superior to the parallel-plate channel in intensifying heat transfer.
No takes yet. Share an insight, caveat, or question.
Ali et al. (1992) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: