Why the study?
Remote patient monitoring is needed for resource limitations and infection control, but current sensors require physical contact that can cause discomfort or non-adherence.
Does a novel contact-free optical system accurately measure heart and respiratory rate compared to a standard bedside monitor?
Does a novel contact-free optical system accurately measure heart and respiratory rate compared to a standard bedside monitor?
A novel contact-free optical system demonstrated over 99% accuracy in detecting heart and respiratory rate compared to standard bedside monitors.
Answers are grounded in this paper and cite their sources.
May enable comfortable remote vital-sign monitoring; leaves open larger validation before clinical adoption.
There is a growing need for remote monitoring of patients due to a lack of resources and infection control. Current systems use sensors that require constant physical contact with the user, which may result in discomfort or lack of adherence. In the present study, we evaluated the accuracy of a new contact-free system to monitor heart and respiratory rate. Study participants were measured simultaneously using two devices: a contact-free optical system that measures nano-vibrations and movements (investigational device, “Gili Pro BioSensor”) and a standard reference bed-side monitor, inclusive of an electrocardiogram and capnograph modules (Mindray®). Co-primary endpoints included HR and RR accuracy in subjects without active arrhythmias for HR, and for all study populations for RR (i.e., for subjects with and without active arrhythmias). Confirmatory secondary endpoints included HR scored continuously for all study populations, inclusive of subjects with arrhythmias. The present study included 115 patients who completed study procedures. Mean age was 66 ± 14.6 (range 29–93) with 60% males, 31% obese patients (i.e., BMI > 30 kg/m2, range 17–44) and 56% measured in a chair. For the dichotomised accuracy analysis, both co-primary endpoint for HR and RR resulted in 100% accuracy (95% CI: HR 98.8–100%; RR 98.9–100%), whereas for the confirmatory secondary analysis, 99.1% of the HR measurements across subjects with and without active arrhythmias were deemed accurate (95% CI: 97.4–99.8%). The current study demonstrated over 99% accuracy in detecting heart and respiratory rate using a novel contact-free optical system.
No takes yet. Share an insight, caveat, or question.
Havakuk et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: