Why the study?
Does bronchodilator inhalation improve advanced lung function parameters differently depending on baseline FEV1 in COPD patients and controls?
Does bronchodilator inhalation improve advanced lung function parameters differently depending on baseline FEV1 in COPD patients and controls?
Volume and resistance responses to bronchodilators do not follow the flow response measured with FEV1 and may be used as a complement to identify responders in COPD.
May support volume-based assessment in severe COPD; leaves open whether it refines reversibility testing or management.
Background: COPD is defined as partly irreversible airflow obstruction. The response pattern of bronchodilators has not been followed in advanced lung function parameters. Purpose: The aim of this study was to investigate bronchodilator response pattern in advanced lung function parameters in a continuous fashion along forced expiratory volume in 1 second (FEV 1 ) percent predicted (%p) in COPD patients and controls. Patients and methods: Eighty-one smokers/ex-smokers (41 controls and 40 COPD) performed spirometry, body plethysmography, impulse oscillometry and single-breath helium dilution carbon monoxide diffusion at baseline, after salbutamol inhalation and then after an additional inhalation of ipratropium. Results: Most pulmonary function parameters showed a linear increase in response to decreased FEV 1 %p. The subjects were divided into groups of FEV 1 %p <65 and >65, and the findings from continuous analysis were verified. The exceptions to this linear response were inspiratory capacity (IC), forced vital capacity (FVC), FEV 1 /FVC and expiratory resistance (R ex ), which showed a segmented response relationship to FEV 1 %p. IC and FVC, with break points (BP) of 57 and 58 FEV 1 %p respectively, showed no response above, but an incresed slope below the BP. In addition, in patients with FEV 1 %p <65 and >65, response of FEV 1 %p did not correlate to response of volume parameters. Conclusion: Response of several advanced lung function parameters differs depending on patients’ baseline FEV 1 %p, and specifically response of volume parameters is most pronounced in COPD patients with FEV 1 %p <65. Volume and resistance responses do not follow the flow response measured with FEV 1 and may thus be used as a complement to FEV 1 reversibility to identify flow, volume and resistance responders.
No takes yet. Share an insight, caveat, or question.
Jarenbäck et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: