Key result
Four-dimensional echocardiography demonstrated excellent correlation with 4D cardiac magnetic resonance for assessing left-ventricular ejection fraction in rats.
Why the study?
Does 4D echocardiography correlate with 4D CMR for assessing left-ventricular ejection fraction in rats?
Does 4D echocardiography correlate with 4D CMR for assessing left-ventricular ejection fraction in rats?
4D echocardiography provides a precise and highly reproducible alternative to 4D CMR for in-vivo assessment of ventricular function in preclinical rat models.
Answers are grounded in this paper and cite their sources.
Supports 4D echocardiography for LVEF assessment in rat models; leaves open human translation before clinical use.
Preclinical cardiovascular research is the foundation of our understanding and broad knowledge of heart function and cardiovascular disease. Reliable cardiac imaging modalities are the basis for applicable results. Four-dimensional cardiac magnetic resonance (4D CMR) has been set as the gold standard for in-vivo assessment of ventricular function in rodents. However, technical improvements in echocardiography now allow us to image the whole heart, which makes four-dimensional echocardiography (4DE) a possible alternative to 4D CMR. To date, no study has systematically assessed 4DE in comparison with 4D CMR in rats. In total we studied 26 juvenile Sprague-Dawley rats (Crl: CD (SD) IGS). Twenty rats underwent echocardiographic imaging (2D and 4D) and 4D CMR. Five of those rats underwent a ligation of the superior and inferior vena cava to reduce the cardiac inflow as a disease model. Six additional rats were used to assess reproducibility of echocardiography and underwent three echocardiographic examinations. 4D CMR was performed on a 7T scanner; 2D and 4D echocardiography was conducted using a 40 MHz transducer. Correlation between 4D CMR, 4DE and 2DE for left-ventricular ejection fraction (LVEF) was assessed. An excellent correlation was observed between 4DE and 4D CMR ( r = 0.95, p < 0.001). Correlation of 2DE and 4D CMR was weak ( r = 0.57, p < 0.01). 4DE provides results that are equally precise as 4D CMR and highly reproducible with less technical effort than 4D CMR.
No takes yet. Share an insight, caveat, or question.
Stegmann et al. (2018) studied Ventricular function assessment (n=26). Four-dimensional echocardiography (4DE) vs. 4D cardiac magnetic resonance (4D CMR) was evaluated on Correlation for left-ventricular ejection fraction (LVEF) (r = 0.95, p=< 0.001). Four-dimensional echocardiography demonstrated excellent correlation with 4D cardiac magnetic resonance for assessing left-ventricular ejection fraction in rats.
Synapse has enriched 10 related papers. Consider them for comparative context: