Key result
Cardiac magnetic resonance and transoesophageal echocardiography showed strong correlation for determining ejection fraction in rats, with CMR demonstrating excellent reproducibility.
Why the study?
How do 1.5 T cardiac magnetic resonance and transoesophageal echocardiography compare to transthoracic echocardiography in determining ejection fraction in rats post-myocardial infarction?
Cross-Sectional (n=20)
How do 1.5 T cardiac magnetic resonance and transoesophageal echocardiography compare to transthoracic echocardiography in determining ejection fraction in rats post-myocardial infarction?
CMR, TTE, and TOE are all viable options for evaluating ventricular function in rats, with CMR offering distinct advantages in image quality and reproducibility.
Answers are grounded in this paper and cite their sources.
Supports modality selection for rat post-MI EF assessment; leaves open clinical translation and standardization.
In vivo assessment of ventricular function in rodents has largely been restricted to transthoracic echocardiography (TTE). However 1.5 T cardiac magnetic resonance (CMR) and transoesophageal echocardiography (TOE) have emerged as possible alternatives. Yet, to date, no study has systematically assessed these three imaging modalities in determining ejection fraction (EF) in rats. Twenty rats underwent imaging four weeks after surgically-induced myocardial infarction. CMR was performed on a 1.5 T scanner, TTE was conducted using a 9.2 MHz transducer and TOE was performed with a 10 MHz intracardiac echo catheter. Correlation between the three techniques for EF determination and analysis reproducibility was assessed. Moderate-strong correlation was observed between the three modalities; the greatest between CMR and TOE (intraclass correlation coefficient (ICC) = 0.89), followed by TOE and TTE (ICC = 0.70) and CMR and TTE (ICC = 0.63). Intra- and inter-observer variations were excellent with CMR (ICC = 0.99 and 0.98 respectively), very good with TTE (0.90 and 0.89) and TOE (0.87 and 0.84). Each modality is a viable option for evaluating ventricular function in rats, however the high image quality and excellent reproducibility of CMR offers distinct advantages even at 1.5 T with conventional coils and software.
No takes yet. Share an insight, caveat, or question.
Richardson et al. (2013) conducted a cross-sectional in surgically-induced myocardial infarction (n=20). Cardiac magnetic resonance (CMR) and transoesophageal echocardiography (TOE) vs. Transthoracic echocardiography (TTE) was evaluated on Correlation between techniques for ejection fraction determination (ICC 0.89). Cardiac magnetic resonance and transoesophageal echocardiography showed strong correlation for determining ejection fraction in rats, with CMR demonstrating excellent reproducibility.
Synapse has enriched 10 related papers. Consider them for comparative context: