Key result
Coronary computed tomography angiography was successfully implemented for routine detection of cardiac allograft vasculopathy, providing good-excellent image quality in 92% of patients.
Why the study?
Cardiac allograft vasculopathy affects long-term outcomes in heart transplant patients, prompting evaluation of the feasibility of coronary computed tomography angiography for routine CAV detection.
Is coronary computed tomography angiography feasible and effective for the routine detection of cardiac allograft vasculopathy in heart transplant patients?
Observational (n=172)
No
Is coronary computed tomography angiography feasible and effective for the routine detection of cardiac allograft vasculopathy in heart transplant patients?
CCTA is a feasible, low-radiation imaging modality for routine surveillance of cardiac allograft vasculopathy in heart transplant recipients, potentially reducing the need for invasive testing.
CCTA feasible for routine CAV surveillance in HTx patients; leaves open whether it improves outcomes over perfusion imaging.
Cardiac allograft vasculopathy (CAV) is an accelerated form of coronary artery disease that affects long-term outcomes in heart transplant (HTx) patients. We prospectively evaluated the feasibility of coronary computed tomography angiography (CCTA) for the detection of CAV during clinical implementation at our center. All consecutive HTx patients >4 years post-transplant were actively converted from myocardial perfusion imaging to CCTA for the annual assessment of CAV. Between February 2018 and May 2019, 129/172 (75%) HTx patients underwent a CCTA. Renal impairment (n = 21/43) was the most frequent reason for patients could not undergo CCTA. CCTA image quality was good-excellent in 118/129 (92%) patients, and the radiation dose was 2.1 (1.6-2.8) mSv. CCTA showed obstructive CAV in 19/129 (15%) patients. Thirteen (10%) patients underwent additional tests, of which 8 patients underwent coronary revascularization within 90 days of CCTA. After 1 year, 3 additional coronary angiograms were performed, resulting in one revascularization in a patient with known severe CAV who developed ventricular tachycardia. One myocardial infarction after coronary stenting and 2 non-cardiac deaths were observed. CCTA can be successfully implemented for routine detection of CAV with good image quality and low radiation dose. CCTA allows CAV evaluation with the limited need for additional invasive testing.
No takes yet. Share an insight, caveat, or question.
Nous et al. (2021) conducted an observational in Cardiac allograft vasculopathy (n=172). Coronary computed tomography angiography (CCTA) vs. Myocardial perfusion imaging was evaluated on Feasibility of CCTA (good-excellent image quality). Coronary computed tomography angiography was successfully implemented for routine detection of cardiac allograft vasculopathy, providing good-excellent image quality in 92% of patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: