Key result
Epicardial conductance (CEPI) demonstrated excellent diagnostic efficiency to characterize significant coronary stenoses, with steep decreases in distal flow when CEPI was lower than CMICRO.
Why the study?
Coronary assessment has largely relied on pressure ratios and resistance, lacking an intuitive method using identical units to express blood deliverability across both domains.
Does the assessment of epicardial (CEPI) and microvascular conductance (CMICRO) accurately characterize functional stenosis severity in patients with stable coronary artery disease?
Observational (n=261)
Does the assessment of epicardial (CEPI) and microvascular conductance (CMICRO) accurately characterize functional stenosis severity in patients with stable coronary artery disease?
Simultaneous assessment of epicardial and microvascular conductance is feasible and provides excellent diagnostic efficiency for detecting clinically relevant coronary stenoses.
Answers are grounded in this paper and cite their sources.
Enables unified conductance assessment of epicardial and microvascular disease; hypothesis-generating pending prospective validation.
AIMS: Assessment of the coronary circulation has been based largely on pressure ratios (epicardial) and resistance (micro-vessels). Simultaneous assessment of epicardial (CEPI) and microvascular conductance (CMICRO) provides an intuitive approach using the same units for both coronary domains and expressing the actual deliverability of blood. The aim of this study was to develop a novel integral method for assessing the functional severity of epicardial and microvascular disease. METHODS AND RESULTS: We performed intracoronary pressure and Doppler flow velocity measurements in 403 vessels in 261 patients with stable coronary artery disease. Hyperaemic mid-to-late diastolic pressure and flow velocity (PV) relationships were calculated. The slope of the aortic PV indicates the overall conductance and the slope of the distal PV relationship represents CMICRO. The intercept with the x-axis represents zero-flow pressure (Pzf). CEPI was derived from microvascular and overall conductance. Median CEPI was higher compared to CMICRO (4.2 [2.1-8.0] versus 1.3 [1.0-1.7] cm/s/mmHg, p<0.001). CMICRO was independent of stenosis severity (1.3 [1.0-1.7] in FFR ≤0.80 versus 1.4 [1.0-1.8] in FFR >0.8, p=0.797). ROC curves (using FFR and HSR concordant vessels as standard) demonstrated an excellent ability of CEPI to characterise significant stenoses (AUC 0.93). When CEPI<CMICRO, a decrease in flow velocity and coronary pressure (optimal cut-off value 0.97, AUC 0.90) was demonstrated. CONCLUSIONS: A comprehensive assessment of separate CEPI and CMICRO was feasible. CEPI has a remarkable diagnostic efficiency to detect a clinically relevant stenosis. When CEPI<CMICRO, distal flow and pressure decrease steeply, indicating myocardial ischaemia. CMICRO can be used to explore the severity of microvascular disease.
No takes yet. Share an insight, caveat, or question.
Hoeven et al. (2019) conducted an observational in Stable coronary artery disease (n=261). Intracoronary pressure and Doppler flow velocity measurements (CEPI and CMICRO) was evaluated on Ability of epicardial conductance (CEPI) to characterise significant stenoses using FFR and HSR concordant vessels as standard (AUC 0.93). Epicardial conductance (CEPI) demonstrated excellent diagnostic efficiency to characterize significant coronary stenoses, with steep decreases in distal flow when CEPI was lower than CMICRO.
Synapse has enriched 10 related papers. Consider them for comparative context: