Key result
Off-label use of bioresorbable scaffolds was associated with a significantly higher rate of definite stent thrombosis at 30 days compared to on-label use (1.08% vs 0.26%), though rates equalized by 5 years.
Why the study?
Long-term data were needed to provide real-world insights into how clinical events differ with bioresorbable scaffold implantation for off-label compared with approved indications.
Does the use of everolimus-eluting bioresorbable scaffolds for off-label indications increase the risk of stent thrombosis and target lesion failure compared to on-label indications in patients with coronary artery disease?
Observational (n=3,082)
Yes
Does the use of everolimus-eluting bioresorbable scaffolds for off-label indications increase the risk of stent thrombosis and target lesion failure compared to on-label indications in patients with coronary artery disease?
Odds Ratio: 4.16 (95% CI 0.98–17.61)
Absolute Event Rate: 1.08% vs 0.26%
p-value: p=0.04
Off-label use of bioresorbable scaffolds is associated with increased short-term stent thrombosis and target vessel failure compared to on-label use, though long-term stent thrombosis rates converge by 5 years.
Off-label BRS use may warrant short-term caution; leaves open whether long-term TVF or thrombosis risks differ meaningfully from on-label use.
BACKGROUND: The potential benefits of bioabsorbable stents can be better assessed over the long term. The implantation of bioresorbable scaffold (BRS) in situations with off-label indications provides real-world insights into how clinical events differ in contrast to standard proved indications. OBJECTIVES: The study provides long-term follow-up data about the use of bioresorbable scaffold (BRS) for off-label compared with approved indications. METHODS: Five-year outcome data of an everolimus-eluting, poly-L-lactic acid-based bioresorbable scaffold system (ABSORB, Abbott Vascular, Santa Clara, CA, USA) were evaluated in the prospective, non-interventional, multicenter real-world German-Austrian ABSORB-RegIstRy (GABI-R). The patients were enrolled from a total of 93 centers. Data processing and prospective follow-up were conducted centrally and independently of industry. RESULTS: A total of 3082 patients were enrolled between 2013 and 2016. Most patients were included into the off-label group (2317, 75.2%). ST-elevation myocardial infarction (STEMI) was significantly more common in the off-label group (35.9% vs. 27.8%, p = 0.003), and the extent of coronary heart disease was higher in the off-label group (coronary 3 vessel disease 28.4% vs. 22.4%, p < 0.001). Patients with off-label indications had statistically significant higher rates of stent thrombosis after 30 days (1.08% vs. 0.26%, p = 0.04) and target vessel failure (TVF) after 6 months (4.62% vs. 2.61%, p = 0.02). CONCLUSIONS: The off-label use of BRS is associated with a higher rate of stent thrombosis in the short term and in the long term with higher MACE events considering more complex lesions and a higher morbidity. In the long term, there are no differences regarding stent thrombosis.
No takes yet. Share an insight, caveat, or question.
Huseynov et al. (2025) conducted an observational in Coronary artery disease (n=3,082). Off-label use of bioresorbable scaffold vs. On-label use of bioresorbable scaffold was evaluated on ARC definite stent thrombosis at 30 days (OR 4.16, 95% CI 0.98-17.61, p=0.04). Off-label use of bioresorbable scaffolds was associated with a significantly higher rate of definite stent thrombosis at 30 days compared to on-label use (1.08% vs 0.26%), though rates equalized by 5 years.