Key result
The walking distance test demonstrated high test-retest reliability over a one-year period in patients with chronic heart failure, with an intraclass correlation coefficient ranging from 0.96 to 0.99.
Why the study?
The study aimed to determine the test–retest reliability of the duplicated six-minute walk test (6MWT) in patients with chronic heart failure and evaluate its variation over time.
Is the six-minute walk test reliable over time in patients with chronic heart failure, and is a single test sufficient for clinical follow-up?
Observational (n=46)
Is the six-minute walk test reliable over time in patients with chronic heart failure, and is a single test sufficient for clinical follow-up?
The six-minute walk test is highly reliable over time in patients with chronic heart failure, indicating that a single test is sufficient for routine clinical follow-up.
Answers are grounded in this paper and cite their sources.
Duplicated 6MWT shows high reliability in HF over 1 year; leaves open whether single tests suffice for clinical monitoring.
Purpose The aims of this study were to determine the test–retest reliability of the duplicated six‐minute walk test (6MWT) in patients with chronic heart failure (HF), and to evaluate its variation over time. Methods Forty‐six patients (9 women) with HF performed duplicated 6MWT every third month for 1 year (5 follow‐ups), for a total of 198 paired tests. The patients completed two 6MWT on the same day with a 45‐min seated rest between tests. Results The mean distance in metres, for the first (6MWT1) versus the second (6MWT2), for each follow‐up, was 408 ± 100 versus 411 ± 96, 449 ± 94 versus 465 ± 94, 464 ± 96 versus 473 ± 100, 462 ± 103 versus 468 ± 104 and 472 ± 105 versus 482 ± 107. On average, a marginally, clinically insignificant longer walked distance, 9 m (2.0%), was seen in the second 6MWT. The standard error of a single determination ( S method ) ranged from 2.4% to 3.9% over the study period, and the intraclass correlation coefficient (ICC) ranged from 0.96 to 0.99 (CI 95% 0.94–0.99). The variation over time of ICC or S method was not statistically significant. Conclusion The 6MWT is highly reliable over time in patients with HF, and one test is, therefore, sufficient in clinical follow‐ups.
No takes yet. Share an insight, caveat, or question.
Lans et al. (2020) conducted an observational in Chronic heart failure (n=46). Six-minute walk test (6MWT) vs. Repeated 6MWT was evaluated on Test-retest reliability (intraclass correlation coefficient) (ICC 0.96-0.99, 95% CI 0.94-0.99). The walking distance test demonstrated high test-retest reliability over a one-year period in patients with chronic heart failure, with an intraclass correlation coefficient ranging from 0.96 to 0.99.
Synapse has enriched 10 related papers. Consider them for comparative context: